Product description
Cabinet
is made from durable, high-density EPP. The front metal panel is finished with white powder coating. The circular connection spigots have a diameter of 125 mm (NASHIRA 150 S (E)) or 160 mm (NASHIRA 200 S (E)) and can be rotated to the sides of the unit. The connections are fitted with double-lip seals. Access for maintenance is from the underside of the unit.
Fans
Radial fans with forward-curved blades are fitted on the discharge and intake sides.
Motors
are single-phase EC motors rated at 230 V / 50 Hz.
Heat recovery
The counter-flow plate heat exchanger is made of plastic with a ZZT efficiency of up to 94 per cent. The NASHIRA S E is equipped with a counter-flow enthalpy heat exchanger with a ZZT efficiency of up to 90 per cent and a ZZV efficiency of up to 78 per cent. The heat exchanger is accessible after removing the unit’s front panel. For summer operation, the unit is fitted with a heat exchanger bypass.
Filter
A G4 filter (ISO coarse 65 per cent) is fitted as standard on the fresh air intake and exhaust air outlet. M5, F7, F9 and CA (activated carbon) filters are available as accessories for the fresh air intake.
Controls
The unit is equipped with constant flow control as standard. It is also fitted with 2 temperature-humidity sensors and 2 temperature sensors, enabling it to operate in automatic mode without the need for user intervention. The wall-mounted controller allows the ventilation intensity to be adjusted, enables manual control of the bypass, activates automatic mode and indicates when the filters are blocked. A wireless control kit is available as an accessory. Further unit settings are made using DIP switches and potentiometers on the controller’s circuit board after removing the front cover. The unit can also be controlled remotely via a mobile app or web interface (SPCM Lite M module required), via Modbus or an external 0–10 V signal. The unit has a contact on the board for activating the BOOST function with a preset run-down time of 10 minutes. A different run-down time can be set using the Modbus protocol.
Electrical connection
A three-core 230 V / 50 Hz power cable is routed from the unit.
Installation
The unit is designed for horizontal installation beneath the ceiling in indoor spaces. By switching the DIP switch, it is possible to configure the unit for a mirrored outlet orientation. The required ambient temperature is at least 12 °C. The unit must be installed in such a way as to ensure sufficient space for removing the front panel, replacing filters, connecting the condensate drain to the waste system with a siphon odour trap, and carrying out periodic inspections of the electrical installation. If the unit is installed above a suspended ceiling, an access panel is required for maintenance.
Accessories
• SF-P 138 negative-pressure trap with odour seal
• KIT RF NASHIRA wireless control kit
• SPCM Lite M communication module
Instructions
If it is necessary to add pre-heating or post-heating to the unit, MBE-AFP 125/0.4, 125/0.8, 160/0.7 or 160/1.4, depending on the unit’s capacity range. Units with an enthalpy heat exchanger may operate without condensate drainage provided the specified conditions are met (outdoor temperature T > -4 °C, indoor temperature T < 22 °C, relative humidity < 60 %).
Information
A compact unit designed for flats or detached houses. It features simple installation and commissioning, the option of automatic operation and highly economical running.
Note
The NASHIRA 150 S E heat recovery unit is part of the ‘New Green Savings’ programme under code SVT37756.
Parameters
| Základní údaje | |
|---|---|
| Motor type | EC |
| Version | Underfloor |
| Exchanger | Plate enthalpy |
| Maximum air flow rate | 150 m³/h |
| Připojení | |
| Diameter of the connection throats | 125 mm |
| Elektrické parametry | |
| Power supply | 230 V |
| Ingress Protection | IP21 |
| Maximum power consumption | 47 W |
| Maximum current | 0,20 A |
| Doplňkové parametry | |
| Boost | Yes |
| Control according to control voltage 0-10 V | Yes |
| Integrated RH sensor for automatic unit operation | Yes |
| Remote management via mobile app/web interface | Yes |
| Další | |
| Weight | 28,50 kg |
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.