S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home
Product description
Casing
is made of electro-galvanised steel sheet and fitted with four mounting feet for installation; the interior is lined with a 50 mm layer of sound-insulating material. Fire reaction class A2-s1, d0 (M0), meaning the enclosure is practically non-combustible, produces very little smoke and no burning droplets drip from the fan casing. The IP55-rated casing is fitted with circular spigots with Class C single-lip seals for connecting flexible hoses or circular ducting. The fan casing cover is secured by four quick-release fasteners.
Impeller
is a radial type with backward-curved blades and is press-fitted directly onto the motor’s external rotor. Designed for airflows from 100 m³/h to 2,400 m³/h and a static pressure of up to 500 Pa.
Motor
A high-efficiency EC motor housed inside the casing with thermal overload protection. Operating temperature range: -20 °C to +40 °C. The electronically commutated motor is suitable for continuous speed control.
Terminal block
is located inside the housing and is accessible after removing the panel with the potentiometer and the on/off safety switch.
Speed control
• manual, integrated potentiometer – standard version
• manual, external potentiometer – continuous speed control via an external potentiometer
• manual, external potentiometer with minimum and maximum speed settings – continuous speed control with the option to limit the speed range using the controller
• manual, four-position switch – selection of one of 4 preset speeds via a switch
• COP (constant pressure control) – automatic maintenance of a constant static pressure in the duct network via a controller
• CAV (constant air volume control) – automatically maintains the set air flow rate regardless of pressure losses in the system (requires a controller fitted with a control module)
• VAV (control via external control signal) – fan output is controlled based on an external analogue signal or values from connected sensors
Installation
is possible in any motor axis position. The fan can be installed in both indoor and outdoor environments in a configuration with ducting on one side and a rain-proof duct fitting on the other. The fan must not transmit mechanical stress to the ductwork. A flexible connection to the ductwork must be used
Instructions
The fans are designed for the ventilation of homes, sanitary facilities, offices and commercial premises. When installing in a suspended ceiling, it is advisable to use flexible hoses, fittings, disc valves and other components. The fans can be used in conjunction with a hygrostat or a hygrostat combined with a thermostat for ventilating damp areas.
Parameters
| Základní údaje | |
|---|---|
| Fan type | radial |
| Mounting | Pipeline |
| Weight | 28,00 kg |
| Max. air temperature | 40 °C |
| Připojení | |
| Diameter of inlet connection pipe | 315 mm |
| Diameter of the connection pipe at the discharge | 315 mm |
| Elektrické parametry | |
| Power supply | 230 V |
| Ingress Protection | IP44 |
| Engine type | EC |
| Maximum power | 238 W |
| Maximum current | 1,00 A |
| Vybavení | |
| Adjustable coasting | No |
| Adjustability | Yes |
| Sound insulation | Yes |
| Ball bearings | Yes |
| Další | |
| Maximum speed | 1 990 min⁻¹ |


Share on Facebook
Tweet
Send email