S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home
Cabinet
is made of durable high density EPP. The front metal panel and sides are powder coated white. Connection circular sockets Ø 125 mm are fitted on the sides of the enclosure. The necks are fitted with a double-edged seal. Revision access is from the front of the unit.
Fans
The unit contains two radial fans with rearward curved blades with EC motor.
Motors
They are single-phase EC with low power consumption, 230 V / 50 Hz. IP21 protection.
Recuperation
The NEMBUS unit is equipped with a counter-current heat exchanger with a heat recovery efficiency of up to 93%. The heat exchanger is accessible by opening the front panel. For summer operation, the unit is equipped with a bypass.
Filters
The unit is fitted with two G4 class (ISO coarse 65%) plate filters for both the intake and exhaust.
Outdoor filters
- AFR-NEMBUS 210 G4/G4 set
- AFR-NEMBUS 210 F7/G4 set
Electrical connections
The unit is designed for direct connection via mains plug. Power supply 230 V / 50 Hz.
Regulation
The unit is equipped with a fully automatic control system, which, in combination with four temperature and relative humidity sensors, ensures continuous speed regulation according to the current requirement, without the need for any further intervention in the control of the unit. In the performance characteristics, curves for individual speeds are indicated (see operating instructions for details). The designer wired controller allows manual fan speed switching, bypass control, activation of the intensive ventilation function (boost), activation of automatic operation, night cooling and filter clogging indication. Other unit settings are made via DIP switches and potentiometers on the unit's control electronics (after removing the front cover). The unit has four pre-set weekly programs, one of which allows automatic operation from a humidity sensor, built-in VOC sensor (optional accessory), or a 0-10V analogue override signal. The unit provides operation down to an outdoor temperature of -15°C with built-in preheat. The unit can be supplemented with a built-in module providing constant air flow control SABIK-NEMBUS-SF. Access to the ConnectAir platform (cloud S&P) is enabled via an external SPCM module.
Mounting
The unit is designed for horizontal ceiling mounting or vertical wall mounting indoors. The required ambient temperature is between 10 and 50 °C. The unit shall be mounted to provide sufficient space for removal of the unit face, replacement of filters, connection of the condensate drain to the SF-P 138 odour trap and for periodic inspection of the wiring. If the unit is mounted above the soffit, an inspection opening for the operator is required.
Accessories
- ED Flex® System circular ductwork
- AIRSENS-CO2 spatial CO2
- NEMBUS-PH integrated preheat
- NEMBUS-VOC integrated VOC sensor
- SONOULTRA flexible silencer
- SABIK-NEMBUS-SF module for constant air flow
Instructions
The unit is not equipped with its own heater as standard. If preheating is required, an integrable NEMBUS-PH module or external MBE and MBW duct heaters with corresponding control elements can be used. After basic set-up by the installer, the unit requires no further adjustment. Filter changes are recommended at least once a year. The design of the ventilation system and its use in buildings with category B gas appliances (gas boilers and open chamber water heaters) or open hearth appliances burning solid or liquid fuels with flue gas exhaust to the chimney is governed by the applicable regulations. Ventilation must comply with the building fire safety regulations.
Information
A complete ventilation system with a small unit designed for ventilation of flats, apartment buildings and family houses. The unit is designed for permanent operation.
Highlights
The NEMBUS 210 heat recovery unit is part of the New Green Savings Programme under the code SVT30864.
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.