Residential air handling units with heat (and humidity) recovery, offering highly energy-efficient operation and intuitive commissioning, designed for the ventilation of detached houses and blocks of flats.
Read more
price on request
Availability: on request [1.11.2026, 00:00] Update
Goods cannot be ordered online.
Contact our sales specialists
or visit our branches.

Insert into the design HVAC program

Product code:
Manufacturer: S&P SISTEMAS DE VENTILACIÓN, S.L.U.   Read moreRead less

S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home

Product description
Product description
Enclosure

is made from durable, high-density EPP. The casing is made from carbon steel with an anti-corrosion finish. The circular connection spigots have a diameter of 125 mm for the NASHIRA Lite 150 and 160 mm for the NASHIRA Lite 200, with the option to rotate the spigots to the side. The spigots are fitted with double-lip seals. Access for maintenance is from the underside of the unit.

Fans

Radial fans with forward-curved blades are fitted on the discharge and intake sides.

Motors

are single-phase EC motors rated at 230 V / 50 Hz.

Heat recovery

The NASHIRA Lite 150 and 200 units are equipped with a counter-flow plate heat exchanger made from a combination of durable polystyrene and aluminium. The heat recovery efficiency reaches up to 89 per cent for the NASHIRA Lite 150 and 88 per cent for the NASHIRA Lite 200. The heat exchanger is accessible after removing the front panel.

Filters

The unit is fitted with G4-class filters (ISO coarse 65 per cent) on the fresh air intake and exhaust air outlets. M5, F7, F9 or CA-class filters are available as accessories for the fresh air intake.

Controls

In its standard configuration, the unit is equipped with constant flow control, which simplifies commissioning and subsequent operation of the unit. The unit’s standard equipment includes a wall-mounted controller, which allows the ventilation intensity to be set to one of three levels. The unit can be controlled remotely via a master control system using the Modbus RTU protocol (the unit is fitted with a physical RS-485 port).

Electrical connection

A three-core 230 V / 50 Hz power cable is connected to the unit.

Installation

The unit is designed for horizontal installation indoors. The required ambient temperature is at least 12 °C. The unit must be installed in such a way as to ensure sufficient space for removing the front panel and subsequently replacing the filters, connecting the condensate drain to the waste system with a siphon odour trap, and carrying out periodic inspections of the electrical installation. If the unit is installed above a suspended ceiling, an access panel must be provided for maintenance.

Information

A small unit designed for flats or detached houses. It is characterised by simple installation and commissioning, the option of automatic operation and highly economical running.

Full description
Parameters
Základní údaje
Motor type EC
Version Underfloor
Exchanger Plate heat recovery
Maximum air flow rate 150 m³/h
Připojení
Diameter of the connection throats 125 mm
Elektrické parametry
Power supply 230 V
Maximum power consumption 110 W
Doplňkové parametry
Remote management via mobile app/web interface Yes
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.

Downloads