Product description
Product description

The iC2-Micro frequency converters are designed for simple and efficient use in common and demanding HVAC and industrial applications. They offer state-of-the-art control, compact design and high energy efficiency.
They operate with unmatched reliability even in complex applications. iC2-Micro will provide user comfort and easy commissioning in a compact design.
iC2-Micro is designed to control fan motor speed in response to system feedback or remote commands from external controllers.
The drive system consists of a custom inverter and motor. Depending on the configuration, the inverter can be used in stand-alone applications or as part of a larger device or installation. The inverters are available with different degrees of protection. They are suitable for installation in control cabinets, on a room wall or in dedicated control rooms.
Always follow the project documentation and operating instructions when installing.

Basic Features

- power supply: 1× 200-240 V / 3× 380-480 V
- power range: 0.37-22 kW
- output frequency: induction motor 0-200 Hz (VVC+ mode), 0-500 Hz (U/f mode)
- control: U/f and VVC+ (sensorless vector control)
- operating temperature: -10 °C to +50 °C
- protection: IP20 as standard, optionally higher version (cover conversion kit to IP21)

Communications and I/O

- RS-485 (Modbus RTU)
- 2× analog input (AI)
- 4× digital input (DI)
- 1× analog output (AO)
- 1× relay output
- internal power supply +10 V and +24 V

Protection and Features

- Electronic thermal motor overload protection
- Temperature monitoring of the inverter heat sink ensures shutdown in case of overheating
- Short circuit protection between motor terminals U, V, W
- If motor phase is missing, the inverter will shut down and report the fault
- In case of mains phase failure, the inverter will shut down or issue a warning
- DC inter-circuit voltage monitoring ensures, the inverter shuts down if the DC inter-circuit voltage is too low or too high
- protection against ground connection of the motor terminals U, V, W
- acoustic noise from the inverter comes from three sources, the DC inter-circuit coils, the internal fan and losses on the RFI filter (acoustic parameters measured according to ISO standards)

Main advantages

- compact size
- easy commissioning
- energy optimized operation
- flexible parameter configuration
- suitable for fans, pumps and HVAC applications

WARNING!

- In residential areas, the inverter may cause radio frequency interference. In this case, additional measures should be used to mitigate the interference.
- Do not use the inverter in applications that do not meet the specified operating conditions and environment. Ensure compliance with the conditions specified in the Operator's Manual.
- Properly sized fuses or circuit breakers must be used for proper protection of the inverter.
- Observe cable types and sizes, stripping lengths, and tightening torques to ensure proper operation of the inverter.

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.