Product description
Cabinet

is made of durable high density EPP. The front metal panel is powder coated white. Connection circular sockets Ø 93 mm with double-edged gasket. The necks can be turned sideways. Revision access is from the front of the unit.

Fans

The unit contains two radial fans with forward curved blades with EC motor.

Motors

They are single-phase EC with low power consumption, 230 V / 50 Hz. IP21 protection

Recuperation

Counter-current heat exchanger with up to 88% efficiency. The heat exchanger is accessible by opening the front panel.

Filters

The unit is fitted with two G4 class (ISO coarse 65%) plate filters for both the intake and exhaust.

Additional filters:

- AFR-ALTAIR 120 filter set G4/G4
- AFR-ALTAIR 120 filter set M5/G4

Electrical connection

A three-core 230 V / 50 Hz power cable is led out of the unit, which is not terminated with a fork (connection to the box).

Regulation

The unit is equipped with a fully automatic control system with flow regulation according to relative humidity. The innovative control system with temperature sensors and humidity sensor ensures fully automatic operation of continuous ventilation without the need for any further intervention in the control of the unit. A wired controller is included, which allows switching from automatic to manual operation with the possibility of switching between three power speeds. The system indicates filter contamination by an acoustic signal or LED indication on the connected controller. The unit is equipped with a contact to activate the BOOST function.

Mounting

The unit is designed for vertical wall mounting indoors. The required ambient temperature is between 10 and 50 °C. The unit must be mounted so as to provide sufficient space for removing the unit face, changing filters, connecting the condensate drain to the waste with a siphon odour stop and for carrying out periodic wiring inspections. If the unit is mounted behind a bulkhead, an inspection opening for the operator is required.

Noise

The sound power level at the casing is given in the table of technical parameters.

Instructions

The unit is "plug&play", which means really simple commissioning with no complicated setup once the unit is installed. MBE(-AFP) or MBW pipe heaters can be used if preheating or reheating is required to be added to the unit. Filter changes are recommended at least once a year. The design of the heat recovery system and its use in buildings with gas appliances of category B (gas boilers and open chamber water heaters) or open hearth appliances burning solid or liquid fuels with flue gas exhaust to the chimney is governed by the applicable regulations. Ventilation must comply with the normative regulations on fire safety in buildings and must not contravene fire regulations.

Information

A complete ventilation system with a small unit designed for ventilation of apartments, apartment buildings and houses. The unit is designed for permanent operation.

Notice

The ALTAIR 120 V recuperation unit is part of the New Green Savings Programme under the code SVT30839.

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.