S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home
Cabinet
is made of steel sheet coated with black epoxy paint, the brackets and screws are also electroplated.
Running wheel
is made of Al alloy. The impeller is statically and dynamically balanced, the operating temperature range is from -20 to +55 ˚C (sizes 15-710 except TCBT/4-710) or from -20 to +40 ˚C (size 800 and TCBT/4-710).
Motor
asynchronous with short armature, stator with cooling fins, black epoxy lacquer finish with Class F insulation. grease-filled ball bearings for life. IP55 protection. For sizes 710-1000, consult our engineers for IA/IN and te values.
Speed control
By default, fans cannot be electrically or electronically controlled. PTC motors with thermal protection can be supplied on request, regulated by recommended frequency converters.
Rotation direction
It is possible to order an impeller for the opposite direction of rotation. For the wall-mounted version, the standard airflow is from the motor to the impeller, for the ducted version it is the other way around.
Clamps
is in a non-explosive design. The terminal box is located on the motor (wall-mounted version) or on the casing (ducted version).
Mounting
Fans in each position of the motor axis. The cabinet must not transmit mechanical stresses from the piping. A flexible connection to the piping must be used.
Noise
emitted by the fan is given in the tables, measured in the free acoustic field at a distance equal to three times the impeller diameter (but not less than 1,5 m), on the intake side.
Instructions
Inquire about special designs and currently available special accessories. Ask for information on delivery dates. Please note: the fans are in a special design for the Czech Republic. Spare parts supplied as standard by the manufacturer or other commercial organisations cannot be used. The TCBT/4-315 Ex fans can only be operated in a 3 x 400 V network in a Y connection. The values of In, Ia/In and Te specified in the fan certificates are the decisive basis for the installation of the safety elements and thus the safe operation of the fans. These values must be checked carefully after delivery of the fan.
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.