Cabinet
It is made of ABS, resistant to deformation, two-component finish in glossy finish, colour white RAL 9016. There is a non-return flap on the discharge. The front grille contains a filter and silencer. The enclosure shall include a filter change indicator. ECO-AEC has a discharge outlet to the rear for pipes with a diameter of 75-80 mm. ECO-UEC has a discharge outlet to the top (optionally to the rear) for pipes with a diameter of 75-80 mm. It also has a preparation for three outlets to vent the toilet bowl (Ø 40/50 mm) or adjacent rooms (Ø 75/80 mm). Nozzles are not included in the delivery of the fan.
Running wheel
is radial with forward curved blades, press-fitted to the outer rotor.
Motor
Maintenance-free EC motor with the highest energy efficiency class. The motor has a built-in thermal overload protector, max. ambient temperature is 40 ˚C. IPX5 protection.
Square box
is accessible by removing the front grille in the fan housing.
Mounting
ECO-AEC is mounted on the wall or on the ceiling.
The ECO-UEC is mounted flush to the plaster or to the ceiling, in both horizontal and vertical positions. The extension for extraction of adjacent spaces can be positioned on three sides of the enclosure as required, see illustration. The fan is supplied assembled, the cabinet is covered with a temporary anti-fouling lid and is replaced with a loose-fitting faceplate after installation. The inaccuracy of the brickwork can be compensated by rotating the faceplate by up to approx. 10˚.
Options
- No timing
- NR delayed start-up 1 min. and timing 8 min.
- SILENT ECO-UEC Z concealed version, rear outlet
- SILENT ECO-UEC H concealed version, top outlet
- SILENT ECO-AEC concealed version, rear outlet
Air-conditioning accessories
- ECO-UEC does not include an attachment for extraction of secondary spaces, to be ordered separately.
- 40/50 mm extension for ECO-UEC toilet bowl extraction extension
- 75/80 mm extension for ECO-UEC side room extraction extension
- SILENT plastic bracket type MBK
- SILENT metal bracket type MBM
- Sump 100/75, 100/50 extension for connection of plate valve DN100 mm for extraction from second room
- IT 100 plate valve (K 7.2)
- LG 100 outdoor plastic grille (K 7.1)
- PER 100 outdoor check valve (K 7.1)
- PT door inlet grille (K 7.1)
- Aluflex®, Sonoflex®, Greyflex®, Semiflex® flexible hoses (K 7.3)
EL Accessories
Pre-programmed EC modules
- EC 02 timing (0 min on, 4 min off*)
- EC 03 GL base flow 20 m³/h (stage 1), continuous operation*
- EC 04 NRGL timing (1 min on, off 8 min*), basic flow rate 20 m³/h (stage 1), continuous operation*
- EC 05 NREGL timing (on 0 min, off 4 min*), basic flow rate 20 m³/h (stage 1), continuous operation*
- EC 06 NR timing (on 1 min,off 8 min.*)
- EC 07 HYBEW0-10 automatic humidity sensor control, automatic motion sensor control, 0-10 V / PWM (if no base flow or timing is required)
Additional components
- EC-HYM relative humidity sensor
- EC-BEW motion sensor
- EC-10VPWM cable for external analogue 0-10 V signal
* For automatic humidity sensor control, automatic motion sensor control and 0-10 V / PWM, no additional programming is required if the required sensors are available.
Instructions
The fans are suitable for very demanding interiors, architectural solutions and for the extraction of odours directly from sanitary ware. The fans can be easily adjusted using the ECO EC Android app.
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.