RESPIRO 150 RD N small ventilation unit with heat recovery

A small ventilation unit with heat recovery suitable for new buildings or renovations as a replacement for existing negative pressure ventilation with fans.
Read more
B2B clients will see their prices after logging in
12 069,00 CZK excl. VAT
14 603,49 CZK incl. VAT
Availability: In stock [19.1.2026, 16:10] Update

Insert into the design HVAC program

Product code: SP304100130
EAN: 8445325138564
Product description
Cabinet

is made of durable hardened white plastic. The heat exchanger part of the unit allows for installation in a 250-500 mm thick wall. In the case of a larger wall thickness, a 700 mm long extension can be added as an option for the RESPIRO 150 N (RD) unit or a 500 mm long extension can be connected to the existing tube of the RESPIRO 100 N (RD) unit using an external coupling (SN 100). The inner part of the unit is equipped with a design front cover.

Fans

The unit is fitted with a reversible axial fan with DC motor and is designed for continuous operation.

Motor

Commutatorless motor with electronic control and low power consumption up to an operating temperature of -20 °C to 50 °C.

Regeneration

It is equipped with a regenerative heat exchanger made of ceramic material. For easy maintenance and servicing, the heat exchanger is accessible by removing the inner part of the unit containing the fan.

Filters

A G3 class filter (ISO coarse 45%) is located on both sides of the heat exchanger.

Regulation

The standard design of the unit allows manual adjustment of the ventilation intensity in 3 stages via a remote control. The RD variant has a fully automatic mode which, based on the integrated humidity sensor, provides continuous speed control without the need for any further intervention in the unit control. The unit in the RD variant can also be controlled manually. The remote control can be used to set 3 ventilation intensity levels and to change between supply and extract, supply only and extract only modes. In addition, the units in the RD variant can be interconnected to ventilate antagonistically in the intake and exhaust mode. In the "alternate" mode, the standard flow direction change interval is set to 70 s.

Mounting

The unit is designed for internal wall installation and can only be installed in the horizontal axis of the heat exchanger body with a minimum 1% inclination to the outside edge of the wall. The telescopic tube containing the heat exchanger, fan and filters can be adapted to the wall thickness in the range of 250-500 mm (longer length with optional accessories). An internal design cover and an external facade grille are also included.

Electrical connection

A three-core 230 V/50 Hz power cable is routed from the unit.

Options

- RESPIRO 100 N, 150 N - 3 speeds, manual control, remote control
- RESPIRO 100 RD N, 150 RD N - 3 speeds, operating mode setting, remote control, automatic operation depending on humidity, possibility of interconnecting multiple units

Accessories

PULSE 160 T700 mounting tube length 700 mm
RESPIRO 100 N (RD) connecting extension tube length 500 mm

Information

Local ventilation unit designed for new constructions and renovations of family and apartment houses. It is characterized by its easy installation with only minor structural modifications required (opening in the building envelope), which makes it an ideal solution especially for renovations.

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.

Downloads