New version of the catalogue Mass ventilation of garages!
In the catalogue we present suitable fan types and possible ventilation methods for specific garage buildings.
The design method using Computational Fluid Dynamics (CFD) simulation software is commented on.
The catalogue can be downloaded here.

MBE 200/2,0 R2 electrical heater battery

Controlled electric heaters for circular pipes
Read more
B2B clients will see their prices after logging in
13 530,00 CZK excl. VAT
16 371,30 CZK incl. VAT
Availability: In stock [27.4.2024, 04:10] Update

Product code: TK510300090
Product description
Information

- the cabinet is made of galvanized sheet metal, includes terminal block, internal installation and heating power regulator including power element cooler
- the heating rods are made of stainless steel
- it is equipped with two thermostats, working (60°C) and safety (switches off at 120°C)
- the reset button of the safety thermostat is located on the cabinet, during installation it is necessary to position the heater with regard to the inspection activity
- continuous regulation is carried out by supplying the control voltage with the range of 0-10 V depending on the control deviation or by the built-in temperature regulator
- the heater is equipped with its own temperature regulator with inputs for TGBK sensors
- the regulator allows connection with the Unireg® control unit, or with a complete Digireg® control unit

Technical parameters
- control voltage 0 to 10 V DC
- current draw at 10 V control voltage up to 10 mA
- control voltage range for 0-100% of heater output is approx. 0.6% of the heater output (more details on request)
- operating temperature on the heaters (at ambient temperature 40 °C) is up to 85 °C
- maximum temperature on the heaters with electronic limitation in case of insufficient cooling up to 100 °C
- heater switching period approx. 20 s
- control circuit is galvanically isolated from the mains voltage, maintaining conditions for SELV circuits
- for control systems, which cannot supply control voltage with 10 mA current, PS-21 converter is available
- protection IP43
- they are mounted behind the fan in the direction of air flow, approx. 1 m of pipe must be inserted between the fan and heater
- when switching off the fans, the dampers in the system may be closed only after the bars have cooled down, otherwise there is a risk of damage to the heater and other equipment.
- Caution! The electric heater must have a minimum speed through the heating coils of 1.5 m/s to maintain proper operation. Failure to maintain this speed will cause the heating coils to overheat and disable the heater's thermal protection. This significantly reduces the life of the heating coils.

- In addition to the standard performance range, the following designs are available:
- MBE-100 R2 - 0,8 kW
- MBE-125 R2 - 0,4/0,8 kW
- MBE-160 R2 - 0,7/1,4 kW
- MBE-200 R2 - 2/4/6/9 kW
- MBE-250 R2 - 1/2/3/4/9 kW
- MBE-315 R2 - 12/15 kW
- MBE-355 R2 - 6/12/15/18 kW
- MBE-400 R2 - 6/12/15/18 kW
- MBE-500 R2 - 6/12/15/18 kW

Notice

When shutting down the HVAC system, a fan run time of at least 2 minutes must be provided to cool the heating rods. Failure to do so may damage the heater and other equipment."