EDF-CO2-D detector of CO2 concentration

Monitoring device for precise CO₂ monitoring.
Read more
B2B clients will see their prices after logging in
4 996,00 CZK excl. VAT
6 045,16 CZK incl. VAT
Availability: In stock [20.8.2025, 16:10] Update

Product code: PX200100010
EAN: PX200100010
Product description

EDF-CO2-D is a portable monitoring device for accurate CO2 monitoring. In addition to measuring the CO2 concentration, it also allows you to measure the ambient temperature. It uses NDIR optical technology to ensure long-term stability. It is a small desktop device suitable, together with a power supply, for daily operation in the home. The device has a programmable alarm to indicate concentration exceedances and a memory to allow checking of daily readings.

Features

- Built-in logger can record 48 CO2 and temperature readings over the past 24 hours; one recording every 30 minutes.
- Max/Min mode allows maximum and minimum CO2 concentrations to be recorded since last power-up.
- Alarm Mode indicates a concentration of 1000 PPM, the ASHRAE recommended limit, with an audible signal. The alarm level can be changed and the audible indication can be turned off.
- RCFS Mode is used to restore the original factory settings.

Warning!

Cannot be used as a switch contact to control the device (only when using the optional EDF-CO2-D-RE accessory).

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.

Downloads
Technical sheets, manuals and declarations
Datasheet .pdf (78.64 kB)
Operating Instructions .pdf (602.95 kB)
Contact Us