Small radial fans suitable for demanding interiors and architectural solutions.
Read more
B2B clients will see their prices after logging in
6 299,00 CZK excl. VAT
7 621,79 CZK incl. VAT
Availability: In stock [26.10.2026, 16:10] Update

Insert into the design HVAC program

Product code: SP125200040
EAN: 8413893705440
Manufacturer: S&P SISTEMAS DE VENTILACIÓN, S.L.U.   Read moreRead less

S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home

Product description
Product description
Housing

The housing is made of ABS and is white in colour. Airflow is directed rearwards; the outlet diameter is 99 mm. It is designed for wall or ceiling mounting. The fans come with a non-return valve included in the pack, which can be used when the fan is operating intermittently.

Impeller

The impeller is a radial type with forward-curved blades, press-fitted onto the EC motor shaft.

Motor

The motor is an EC motor with high efficiency and low power consumption. It is fitted with a thermal overload protection device; the maximum ambient temperature is 40 ˚C. Protection rating: IPX4.

Terminal block

The terminal block is accessible after removing the front grille.

Control

Airflow control operates in two modes. Continuous operation with intermittent ventilation upon activation of an external switch, hygrostat or infrared sensor. Intermittent operation according to the set fan speed upon activation of an external switch, or according to the conditions of the hygrostat, infrared sensor and run-on time. The minimum and maximum speeds are set using potentiometers on the fan’s control electronics after removing the front grille.

Variants

• S – continuous operation at low flow rate; a boost is activated via an external switch. Intermittent operation ensures the fan only starts once the switch is activated.
• T – continuous operation at low flow rate; boost is activated via an external switch; adjustable run-down time 1–30 mins. Intermittent operation ensures that the fan only starts once the switch is activated; after the switch is deactivated, the fan continues to run for the set run-down time.
• H – continuous operation at low flow rate; boost activated by an internal humidity sensor; adjustable run-down time 1–30 mins. Intermittent operation ensures the fan starts automatically only after increased humidity is detected, in accordance with the sensor settings and run-down time.
• M – same functions as H, plus a pull switch fitted directly to the fan housing.
• D – continuous operation at low flow rate; boost is triggered by an internal infrared motion sensor; adjustable run-on time 1–30 mins. Intermittent operation ensures the fan only starts automatically once motion has been detected.

Installation

The fan is installed on a wall or in a suspended ceiling.

Instructions

The fans are suitable for highly demanding interiors and architectural designs.

Full description
Parameters
Základní údaje
Motor type EC
Mounting wall and ceiling mounted
Fan type radial
Připojení
Connection pipe diameter 100 mm
Elektrické parametry
Power supply 230 V
Ingress Protection IPX4
Maximum power 6 W
Další
Max. air temperature 40 °C
Weight 0,57 kg
Doplňkové parametry
Ball bearings Ano
Non-return valve Yes
Adjustable overrun Yes
Hygrostat Yes
Motion sensor No
Adjustability Yes
Particulate filter No
More suction inlets No
Continuous operation with boost Yes
2-speed version No
3-speed version No
Tension switch Yes
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.