Product description
Housing
The housing is made of ABS and is white in colour. Airflow is directed rearwards; the outlet diameter is 99 mm. It is designed for wall or ceiling mounting. The fans come with a non-return valve included in the pack, which can be used when the fan is operating intermittently.
Impeller
The impeller is a radial type with forward-curved blades, press-fitted onto the EC motor shaft.
Motor
The motor is an EC motor with high efficiency and low power consumption. It is fitted with a thermal overload protection device; the maximum ambient temperature is 40 ˚C. Protection rating: IPX4.
Terminal block
The terminal block is accessible after removing the front grille.
Control
Airflow control operates in two modes. Continuous operation with intermittent ventilation upon activation of an external switch, hygrostat or infrared sensor. Intermittent operation according to the set fan speed upon activation of an external switch, or according to the conditions of the hygrostat, infrared sensor and run-on time. The minimum and maximum speeds are set using potentiometers on the fan’s control electronics after removing the front grille.
Variants
• S – continuous operation at low flow rate; a boost is activated via an external switch. Intermittent operation ensures the fan only starts once the switch is activated.
• T – continuous operation at low flow rate; boost is activated via an external switch; adjustable run-down time 1–30 mins. Intermittent operation ensures that the fan only starts once the switch is activated; after the switch is deactivated, the fan continues to run for the set run-down time.
• H – continuous operation at low flow rate; boost activated by an internal humidity sensor; adjustable run-down time 1–30 mins. Intermittent operation ensures the fan starts automatically only after increased humidity is detected, in accordance with the sensor settings and run-down time.
• M – same functions as H, plus a pull switch fitted directly to the fan housing.
• D – continuous operation at low flow rate; boost is triggered by an internal infrared motion sensor; adjustable run-on time 1–30 mins. Intermittent operation ensures the fan only starts automatically once motion has been detected.
Installation
The fan is installed on a wall or in a suspended ceiling.
Instructions
The fans are suitable for highly demanding interiors and architectural designs.
Parameters
| Základní údaje | |
|---|---|
| Motor type | EC |
| Mounting | wall and ceiling mounted |
| Fan type | radial |
| Připojení | |
| Connection pipe diameter | 100 mm |
| Elektrické parametry | |
| Power supply | 230 V |
| Ingress Protection | IPX4 |
| Maximum power | 6 W |
| Další | |
| Max. air temperature | 40 °C |
| Weight | 0,57 kg |
| Doplňkové parametry | |
| Ball bearings | Ano |
| Non-return valve | Yes |
| Adjustable overrun | Yes |
| Hygrostat | Yes |
| Motion sensor | No |
| Adjustability | Yes |
| Particulate filter | No |
| More suction inlets | No |
| Continuous operation with boost | Yes |
| 2-speed version | No |
| 3-speed version | No |
| Tension switch | Yes |
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.