CU2 CFTH rectangular fire damper

Square fire dampers serving as a closure of air ducts in case of fire.
Read more
B2B clients will see their prices after logging in
12 857,00 CZK excl. VAT
15 556,97 CZK incl. VAT
Availability: on request [23.8.2025, 16:10] Update
Goods cannot be ordered online.
Contact our sales specialists
or visit our branches.

Product code: RT108101830
Product description
Description

The CU2 square fire dampers are used as a closure for air ducts in case of fire. By activating the damper, the spread of combustion products to the adjacent fire compartment is prevented for a specified period of time. The casing of the damper is made of corrosion-protected steel sheet. Certification according to EN 15650. Classification according to EN 13 501-3+A1. Fire resistance of the damper is EI90 or EI120 according to the installation method. Tested according to EN 1366-2 at 500 Pa.

Use

Fire dampers can only be used for air free of mechanical and chemical impurities and in environments without explosion hazards.

Variants

The fire damper is available in the following versions. With fusible link (type CFTH), which activates the closing mechanism at temperatures above 72 °C, or with actuator (type ONE/BFL(T)/BFN). The actuator can be fitted with a 24 V or 230 V actuator. The damper is fitted with a UL inspection opening. On request, dampers with an extended length of 500 mm or ATEX certified can be supplied.

Mounting

The CU2 fire damper is supplied according to the combinations shown in the table (other size ranges available on request). In case of request, it is possible to create so-called batteries (CU2/B) in the fire division structure in dimensions up to 3000 x 1650 mm (width x height) - please contact our technical department. The damper is designed with emphasis on minimum pressure loss. and is suitable for installation in all common building structures such as rigid wall constructions, rigid floors or lightweight partitions. The flap can be installed with the mounting axis in any position.

Highlights

Fire dampers are fire safety devices, therefore it is necessary to comply with the rules prescribed by the standard (training of installers, carrying out regular operational checks, etc.). Ask for information!

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.