CTVT/6-200 N IP55 roof mounted fan

Rooftop radial fans suitable for higher flow rates and higher duct pressure drops.
Read more
B2B clients will see their prices after logging in
34 067,00 CZK excl. VAT
41 221,07 CZK incl. VAT
Availability: on request [20.8.2025, 04:10] Update
Goods cannot be ordered online.
Contact our sales specialists
or visit our branches.

Insert into the design HVAC program

Product code: SP273300080
EAN: 8413893352545
Manufacturer: S&P SISTEMAS DE VENTILACIÓN, S.L.U.   Read moreRead less

S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home

Product description
Cabinet

It is designed for horizontal air exhaust for CTHx type, for vertical air exhaust for CTVx type. The fan base is made of galvanized steel sheet, the brackets, grille and screws are also electroplated. The fan shroud and casing are made of Al sheet. The fan motor is mounted outside the air flow. The motor ventilation circuit is separate, using its own radial impeller. There is a ventilation joint around the perimeter of the canopy on the CTHx fan, on the CTVx type the motor ventilation is routed out of the side of the casing.

Iris wheel

The fan is radial with backward curved blades. It is made of galvanized steel sheet and is statically and dynamically balanced.

Clamps

It is accessible by removing the fan canopy, on single phase fans it also contains a start-up capacitor. The protection is IP55.

Motor

is asynchronous with shorted resistance armature, stator with cooling fins, black epoxy lacquer finish. CTH(V)B fan motors are 1-phase for 230 V, CTH(V)T are 3-phase for 230/400 V. The motors are equipped with a thermal fuse as standard. The windings are tropicalised with class F insulation and a permanent operating temperature of -40 to +200 ˚C. Grease-filled ball bearings for life. IP55 protection.

Speed control

is carried out by changing the voltage by electronic or transformer regulators or frequency converters. Motors marked 230/400 V cannot be switched to reduce speed by a Y/Δ switch and can only be operated in Y connection.

Mounting

The fan is to be mounted horizontally using accessories (with the motor axis vertical).

Rotation direction

is only possible in one direction, as indicated by the arrow on the fan housing. The opposite direction of rotation may cause motor overload, and the fan will also experience increased noise.

Noise

emitted by the fan is shown in the tables. The acoustic pressure is measured in the free acoustic field at a distance of 3 m at operating point 2 of the power characteristic (intake/exhaust).

Instructions

Fans are suitable for stack draft boosting and general air handling applications.

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.

Downloads
Technical sheets, manuals and declarations
Catalogue sheet .pdf (764.87 kB)
Instructions .pdf (438.75 kB)
Declaration of conformity .pdf (360.81 kB)
CAD files
2D .dwg (28.63 kB)
3D .dwg (223.70 kB)
2D .dxf (111.59 kB)
3D .dxf (177.73 kB)
Contact Us