Cabinet
is made of durable high density EPP. The front metal panel is powder coated white. Connection circular sockets with double-edged gasket Ø 93 mm. The necks can be turned sideways. Revision access is from the front of the unit.
Fans
The unit contains two radial fans with forward curved blades with EC motor.
Motors
They are single-phase EC with low power consumption, 230 V / 50 Hz. IP21 protection.
Recuperation
Counter-current heat exchanger with up to 88% efficiency. The exchanger is accessible by opening the front panel.
Filters
The unit is fitted with two G4 class (ISO coarse 65%) plate filters for both the intake and exhaust.
Outdoor filters
- AFR-ALTAIR 120 filter set G4/G4
- AFR-ALTAIR 120 filter set M5/G4
Electrical connection
A three-core 230 V / 50 Hz power cable is led from the unit, which is not terminated with a fork (connection to the box).
Regulation
The unit is equipped with a fully automatic control system with flow regulation according to relative humidity. The innovative control system with temperature sensors and humidity sensor ensures fully automatic operation of continuous ventilation without the need for any further intervention in the control of the unit. A wired controller is included, which allows switching from automatic to manual operation with the possibility of switching between three power speeds. The system indicates filter contamination by an acoustic signal or LED indication on the connected controller. The unit is equipped with a contact to activate the BOOST function.
Mounting
The unit is designed for horizontal installation under the ceiling in interior spaces. The required ambient temperature is between 10 and 50 °C. The unit shall be mounted to provide sufficient space for removal of the unit face, replacement of filters, connection of the condensate drain to the SF-P 138 siphon odour trap and for periodic inspection of the wiring. If the unit is mounted above the soffit, an inspection opening for the operator is required.
Noise
The sound power level at the casing is given in the table of technical parameters.
Instructions
The unit is "plug&play", which means really simple commissioning with no complicated setup once the unit is installed. MBE(-AFP) or MBW pipe heaters can be used if preheating or reheating is required to be added to the unit. Filter changes are recommended at least once a year. The design of the controlled ventilation system with heat recovery and its use in buildings with gas appliances of category B (gas boilers and open chamber water heaters) or with open fire appliances burning solid or liquid fuels with flue gas exhaust to the chimney is governed by the applicable regulations. Ventilation must comply with the normative regulations on fire safety in buildings and must not contravene fire regulations.
Information
A complete ventilation system with a small unit designed for ventilation of apartments, apartment buildings and houses. The unit is designed for permanent operation.
Notice
The ALTAIR 120 H heat recovery unit is part of the New Green Savings Programme under the code SVT30842.