CMPT/4-42-7,5 Ex anti-corrosive explosion proof fan

Acid-resistant fans suitable by their design for long ducts in various technological and air handling applications, in the chemical industry, petrochemistry and laboratories.
Read more
B2B clients will see their prices after logging in
462 048,00 CZK excl. VAT
559 078,08 CZK incl. VAT
Availability: on request [2.8.2025, 16:10] Update

Insert into the design HVAC program

Product code: SP262202100
EAN: 8413893303066
Manufacturer: S&P SISTEMAS DE VENTILACIÓN, S.L.U.   Read moreRead less

S&P SISTEMAS DE VENTILACIÓN, S.L.U.
Llevant, 4
Polígono Industrial Llevant
08150 Parets del Vallès
Barcelona – Spain
consultas[zav]solerpalau[teč]com
www.solerpalau.com/en-en/home

Product description
Cabinet

Spiral radial fan housing is made of antistatic polypropylene, max. air temperature 50 °C (ATEX temperature 40 °C). The fan is supplied as standard with a housing orientation of LG 0 and the discharge throat axis angle can be changed during installation. The fan outlet is circular, the dimensions are shown in the dimensional sketch.

Running wheel

is radial with forward curved blades, made of polypropylene.

Motor

asynchronous with short armature, insulation class F, grease-filled ball bearings for life. Motors are 3-phase for 230/400 V or 3-phase for 400 V. Motor out of air current. Protection IP55. The motor stool is included with the fan and is made of nylon (20A), polypropylene (30, 35) and galvanized steel sheet (42).

Square box

located on the engine.

Mounting

is carried out on the mounting base included with the fan. The fan is started when connected to the pipework for which it is intended, with the intake or discharge closed if necessary, so as not to overload the fan. After start-up, the correct direction of rotation of the impeller must be checked and the current must be measured and must not exceed the rated current of the fan. If the current values are higher, the ductwork alignment must be checked. An overcurrent relay or other suitable motor protection must be included in the fan supply. If the motor overloads, the thermal protection will open the contactor control circuit and disconnect the fan motor. If this motor thermal protection is operating, it usually indicates an abnormal operating mode. In this case, it is necessary to check the piping network alignment and check the electrical parameters of the motor and wiring. If the fans are operated without this protection, the claim for a damaged motor is void. The enclosure must not transmit mechanical stresses from the pipework. A flexible connection to the ductwork must be used.

Instructions

Fans are suitable by their design for long ductwork in various process and air handling applications, in the chemical industry, petrochemical industry and laboratories. They are not suitable for the extraction of wood dust and grit, or other flammable or explosive mixtures.

Warning

Caution, the fans are in a special design for CR. Replacement parts supplied by the manufacturer or trade organisations as standard cannot be used. Please request information on delivery times. The values In, Ia/In and te given in the fan certificates are decisive for the fitting of the safety devices and thus the safe operation of the fans. These values must be checked carefully after delivery of the fan.

Full description
Safety regulations

Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:

• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.