Product description
Functions
Variable air volume controller (VAV controller) is used for autonomous control of the amount of ventilation air of one zone in central ventilation systems.
Construction
The VarioflowBOX COMF EVO VAV controller consists of a pair of tubes (supply and extract) equipped with rails for anchoring to the supporting structure, an electrical switchboard with a VARIOSU 24-10 power supply unit located on the rails of one of the tubes and a small box containing boost timers (Varioboost 24 VAC). For the Varioboost 24 VAC, a DIN rail is provided at the electrical panel for mounting it; alternatively, it can be mounted in a residential panelboard. Both tubes are fitted with a lip seal for connection to the circular pipe. The individual parts are made of galvanized steel sheet. The design differs for dimensions 100 to 160 and 200 to 400. The former have actuators located together with control dampers inside the tubes and the air flow is measured by means of a thermoanemometer. The second design uses flow measurement based on the pressure differential measured by a probe inside each tube. The actuators in this variant are mounted on the casing and are equipped with a pressure air flow sensor. The control valves located in each of the tubes have class 2 leakage according to EN 1751 when closed, except for DN 100, which is only class 3.
Electro
The supply voltage is 1x230 V/50 Hz. The VarioflowBOX COMF EVO is equipped with a 230 V/24 V power supply unit with a connection cable terminated in a 230 V fork with protective conductor. The air flow can be controlled by a 0-10 V analogue signal or by two potential-free contacts (BOOSTs). The BOOST function timer is fixed at 7 or 15 minutes. The regulated air quantity in the inlet tube is the same as in the outlet tube (INPUT = OUTPUT). The degree of protection of the electrical switchboard is IP44. The communication interface for the control system can be selected between Modbus RTU or MP-Bus for dimensions 200, 250, 315 and 400. For dimensions 100, 125 and 160 only MP-bus is available.
Mounting
Wall or ceiling mounted with airflow directions horizontal or vertical. It is necessary to observe the airflow directions shown by the arrows on the tubes. Adequate access must be provided for servicing and maintenance of the controller. In front of the VAV controller, a straight piece of pipe must be provided in the direction of air flow before entering the tubes in the following lengths:
- 1x D for DN 100, 125 and 160
- 2x D for DN 200, 250, 315 and 400
Conditions of operation
Maximum air velocity for dimensions 100, 125 and 160 is 7 m/s, for dimensions 200, 250, 315 and 400 is 12 m/s. The minimum air velocity for dimensions 100, 125 and 160 is 0.3 m/s, for dimensions 200, 250, 315 and 400 is 2 m/s. In the factory, it is possible to set airflow ranges different from the standard ranges listed in the technical parameters table (Vmin and Vmax ranges must be specified when ordering). The maximum possible pressure difference before and after the damper is
900 Pa. The temperature range of the conveyed air should be from 0 °C to + 50 °C and the maximum relative humidity of the flowing air up to 95 % (condensation on the surface or inside the tubes must be prevented). The air flowing through the tubes must be free of adhesive and abrasive impurities to prevent fouling of the flow rate or pressure sensor probes and the control damper.
Accessories
Individual controllers are not required for the VarioflowBOX COMF EVO VAV controller. Please refer to the Control Options section for more detailed information on the controllers.
- Belimo wall-mounted controllers:
- CRP24-B1
- CRA24-B1P
- CRA24-B3
- ABB wall-mounted controllers:
- Design Zoni
- Design Swing (L)
- Design Tango
- Design Levit (M)
- Design Time (Arbo)
- Design Future linear
- Design Solo (carat)
- Design Busch-axcent
- MSKM-KB damper for zoning on the exhaust branch (priority extraction from the kitchen)
Adherence to these instructions should not pose any safety, health or environmental risks in accordance with EC directives (CE marked). The same applies to other products used in the device or during installation. Consider the following warnings:
• Observe the safety instructions to prevent damage to the device or personal injury.
• The technical information in this manual must not be changed.
• It is forbidden to interfere with the motor of the device.
• In order for the device to comply with EC directives, the device must be connected to the mains in accordance with the applicable regulations.
• The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving part and / or live part.
• The device complies with the applicable regulations for the operation of electrical equipment.
• Always disconnect the device from the power supply before carrying out any work on it.
• Appropriate tools must be used when handling or maintaining the device.
• The device must only be used for the purposes for which it is intended.
• This appliance is not intended for use by children under 8 years of age and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible person. The user must ensure that children do not play with the device. Cleaning and maintenance of the appliance must not be carried out by children without supervision.