New version of the catalogue Mass ventilation of garages!
In the catalogue we present suitable fan types and possible ventilation methods for specific garage buildings.
The design method using Computational Fluid Dynamics (CFD) simulation software is commented on.
The catalogue can be downloaded here.

CKB 1500 N IP44 small centrifugal fan

Small radial fans suitable for central ventilation for family houses, sanitary facilities, offices and smaller premises. The fans can be used in conjunction with the SQA sensor for ventilation of common rooms.
Read more
B2B clients will see their prices after logging in
15 888,00 CZK excl. VAT
19 224,48 CZK incl. VAT
Availability: on request [4.5.2024, 16:10] Update

Insert into the design HVAC program

Product code: SP250100015
EAN: 8413893786265
Product description
Cabinet

The cabinet is made of steel sheet, the finish is epoxy lacquer. There is a check valve in the discharge spout. The fan can be supplied with distribution chambers made of PLENUM zinc, which are noise-insulated and allow the connection of up to 7 Sonoflex® ducts or flexible ducts on the intake side of the fan. Unused intake outlets must be sealed with a DFL end cap.

Running wheel

The impeller is a radial impeller with forward curved blades, made of plastic (CKB 800 N) or galvanized steel sheet (CKB 1500 N). The impeller is dynamically and statically balanced.

Motor

The motor is asynchronous, with short armature, starting capacitor and thermal protection. Maximum operating temperature is 70 ˚C, insulation class F, protection class IP44.

Electrical connection

There is a 3-core cable leading from the fan, terminal block not included.

Speed control

Speed control is done by electronic or transformer regulators by changing the voltage.

Mounting

Mounted horizontally or vertically, preferably with the motor axis in the horizontal position, taking into account the bearing life. The fan can be supplied with a PLENUM inlet housing, which must be pressed onto the fan during mounting so that the fan housing is pressed into the foam seal in the groove of the inlet housing. PLENUM is attached to the CKB-N fan with self-tapping screws, and the gap between the fan and the enclosure is filled with a neutral silicone or acrylic sealant. CKB-N fans are mounted via ISA spring-loaded angles on the wall or via KSE vibration isolators on a fixed base.

Instructions

The ventilators are designed as central ventilation for houses, sanitary facilities, offices and smaller premises. Preferably, when installed in the soffit, flexhead and plate valves can be used. Fans can be used in conjunction with an SQA sensor for common room ventilation.

Full description
Downloads
Technical sheets, manuals and declarations
Catalogue sheet .pdf (235.09 kB)
Operating Instructions .pdf (309.75 kB)
Declaration of conformity .pdf (359.49 kB)
CAD files
2D .dwg (175.45 kB)
3D .dwg (571.10 kB)
2D .dxf (350.45 kB)
3D .dxf (729.02 kB)