,AcquisitionDate##OTHER##,Rotation Angle##ANGLE##DEGREES,Rotation Angle Control##ANGLE##DEGREES,ApplicationOfFan##OTHER##,ArticleNumber##OTHER##,AssemblyPlace##OTHER##,AssessmentCondition##OTHER##,AssessmentDate##OTHER##,AssessmentDescription##OTHER##,AtmosphericAcidification##OTHER##,AtmosphericAcidificationPerUnit##OTHER##,Author##OTHER##,BarCode##OTHER##,BIMElementExpiryDate##OTHER##,BIMElementVersion##OTHER##,CapacityControlType##OTHER##,ClimateChange##OTHER##,ClimateChangePerUnit##OTHER##,CoilPosition##OTHER##,ConductorFunction##OTHER##,ContactEmail##OTHER##,ContactTelephone##OTHER##,ContainerMaterial##OTHER##,Description##OTHER##,DirectionOfRotation##OTHER##,DischargePosition##OTHER##,DischargePressureLoss##HVAC_PRESSURE##PASCALS,DischargeVelocity##HVAC_VELOCITY##METERS_PER_SECOND,DrivePowerLoss##HVAC_POWER##WATTS,Air Terminal Velocity Pressure##HVAC_PRESSURE##PASCALS,EfficiencyCurve##OTHER##,Eutrophication##OTHER##,EutrophicationPerUnit##OTHER##,Exclusions##OTHER##,ExpectedServiceLife##OTHER##,FanEfficiency##OTHER##,FanMountingType##OTHER##,FanPowerRate##HVAC_POWER##WATTS,FanRotationSpeed##OTHER##,GlobalTradeItemNumber##OTHER##,GrossWeight##MASS##KILOGRAMS,HasProtectiveEarth##OTHER##,HazardousWaste##OTHER##,HazardousWastePerUnit##OTHER##,ImpellerDiameter##LENGTH##MILLIMETERS,InertWaste##OTHER##,InertWastePerUnit##OTHER##,InstallationDate##OTHER##,InsulationStandardClass##OTHER##,IP_Code##OTHER##,IsExtendedWarranty##OTHER##,LifeCyclePhase##OTHER##,MaintenanceCertificate##OTHER##,MaintenanceCost##OTHER##,MaintenanceFrequency##OTHER##,MaintenanceRegulation##OTHER##,MaintenanceSpecifications##OTHER##,MaintenanceTask##OTHER##,MaintenanceUnit##OTHER##,Manufacturer##OTHER##,MeanTimeBetweenFailure##OTHER##,ModelLabel##OTHER##,MotorDriveType##OTHER##,MotorPosition##OTHER##,NominalAirFlowRate##HVAC_AIR_FLOW##LITERS_PER_SECOND,NominalFrequencyRange##ELECTRICAL_FREQUENCY##HERTZ,NominalPowerRate##ELECTRICAL_POWER##WATTS,NominalRotationSpeed##OTHER##,NominalStaticPressure##HVAC_PRESSURE##PASCALS,NominalTotalPressure##HVAC_PRESSURE##PASCALS,NonHazardousWaste##OTHER##,NonHazardousWastePerUnit##OTHER##,NonRenewableEnergyConsumption##OTHER##,NonRenewableEnergyConsumptionPerUnit##OTHER##,OperationalCriteria##OTHER##,OperationTemperatureRange##OTHER##,OverallEfficiency##OTHER##,PackingCareType##OTHER##,PhotochemicalOzoneFormation##OTHER##,PhotochemicalOzoneFormationPerUnit##OTHER##,PointOfContact##OTHER##,PowerFactor##ELECTRICAL_DEMAND_FACTOR##PERCENTAGE,PressureCurve##OTHER##,ProductionYear##OTHER##,ProductURL##OTHER##,RadioactiveWaste##OTHER##,RadioactiveWastePerUnit##OTHER##,RatedCurrent##ELECTRICAL_CURRENT##AMPERES,RatedVoltage##ELECTRICAL_POTENTIAL##VOLTS,ContactReference##OTHER##,RenewableEnergyConsumption##OTHER##,RenewableEnergyConsumptionPerUnit##OTHER##,ResourceDepletion##OTHER##,ResourceDepletionPerUnit##OTHER##,spFanSize##LENGTH##MILLIMETERS,SerialNumber##OTHER##,ServiceLifeDuration##OTHER##,ShaftPowerRate##HVAC_POWER##WATTS,SoundCurve##OTHER##,spProductQuantity##OTHER##,spTotalProductQuantity##OTHER##,spMotorClass##OTHER##,spProductCode##OTHER##,spEasyVentProductCode##OTHER##,spGenericalProductConfiguration##OTHER##,spProductDescription##OTHER##,spEasyVentProductDescription##OTHER##,spSoundDistance##OTHER##,SpecialInstructions##OTHER##,spIdProject##OTHER##,spMaxAbsorbedCurrent##ELECTRICAL_CURRENT##AMPERES,spProjectLineURL##OTHER##,Arrangement##OTHER##,Model##OTHER##,spProjectName##OTHER##,spPosition##OTHER##,spElectricalPower_Solution##ELECTRICAL_POWER##WATTS,spSpecificPower_Solution##OTHER##,spInletSoundPower##OTHER##,spOutletSoundPower##OTHER##,spBreakOutSoundPower##OTHER##,spShaftPower_Solution##ELECTRICAL_POWER##WATTS,spInletSoundPressure##OTHER##,spOutletSoundPressure##OTHER##,spBreakOutSoundPressure##OTHER##,spReference##OTHER##,spRevision##OTHER##,DischargeType##OTHER##,StratosphericOzoneLayerDestruction##OTHER##,StratosphericOzoneLayerDestructionPerUnit##OTHER##,Throw Distance Medium Velocity##OTHER##,Throw Distance Low Velocity##LENGTH##MILLIMETERS,Throw Distance High Velocity##LENGTH##MILLIMETERS,TotalPrimaryEnergyConsumption##OTHER##,TotalPrimaryEnergyConsumptionPerUnit##OTHER##,Unit##OTHER##,URL##OTHER##,WarrantyContent##OTHER##,WarrantyEndDate##OTHER##,WarrantyStartDate##OTHER##,WaterConsumption##OTHER##,WaterConsumptionPerUnit##OTHER##,WheelTipSpeed##OTHER##,WrappingMaterial##OTHER##,MasterformatCode##OTHER##,MasterformatTitle##OTHER##,Uniclass2.0Code##OTHER##,Uniclass2.0Title##OTHER##,UNSPSCCode##OTHER##,UNSPSCTitle##OTHER##,OmniclassCode##OTHER##,OmniclassTitle##OTHER##,IFCClassification##OTHER##,COBieCategory##OTHER##,Support Bracket Material##OTHER##,PA##LENGTH##MILLIMETERS,PB##LENGTH##MILLIMETERS,PC##LENGTH##MILLIMETERS,PD##LENGTH##MILLIMETERS,PE##LENGTH##MILLIMETERS,PF##LENGTH##MILLIMETERS,PG##LENGTH##MILLIMETERS,PH##LENGTH##MILLIMETERS,PJ##LENGTH##MILLIMETERS,PK##LENGTH##MILLIMETERS "KABT/4-12000/560 2,2KW 400V50 VE","0",90,90,,"0","0","0","0","0",0,0,"0","8413893807724","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-12000/560 2,2KW 400V50 VE....","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893807724",98,"1",0,0,535,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148518600/1",0,0,0,400,"0",0,0,0,0,12000,"0","0",0,"0","0","0","F","5148518600","5148518600","KABT/4-12000/560 2,2KW 400V50 VE...","KABT/4-12000/560 2,2KW 400V50 VE...","KABT/4-12000/560 2,2KW 400V50 VE...","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,844,680,560,326,100,300,400,343.5,51.5 "KABT/4-3000/315 0,25KW 230/400V VE","0",90,90,,"0","0","0","0","0",0,0,"0","8413893807731","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-3000/315 0,25KW 230/400V VE....","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893807731",35,"1",0,0,307,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,328,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148518700/1",0,0,0,0,"0",0,0,0,0,3000,"0","0",0,"0","0","0","F","5148518700","5148518700","KABT/4-3000/315 0,25KW 230/400V VE...","KABT/4-3000/315 0,25KW 230/400V VE...","KABT/4-3000/315 0,25KW 230/400V VE...","0","0","0",0.66,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",505,547,405,315,240,100,152.5,253,225.5,40 "KABT/4-4000/355 0,5KW 230/400V VE","0",90,90,,"0","0","0","0","0",0,0,"0","8413893807748","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-4000/355 0,5KW 230/400V VE....","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893807748",44,"1",0,0,343,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,561,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148518800/1",0,0,0,0,"0",0,0,0,0,4000,"0","0",0,"0","0","0","F","5148518800","5148518800","KABT/4-4000/355 0,5KW 230/400V VE...","KABT/4-4000/355 0,5KW 230/400V VE...","KABT/4-4000/355 0,5KW 230/400V VE...","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",550,592,450,355,230,100,175,275,248,40.5 "KABT/4-6000/450 1,1KW 230/400V VE","0",90,90,,"0","0","0","0","0",0,0,"0","8413893807755","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-6000/450 1,1KW 230/400V VE.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893807755",59,"1",0,0,398,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148518900/1",0,0,0,0,"0",0,0,0,0,6000,"0","0",0,"0","0","0","F","5148518900","5148518900","KABT/4-6000/450 1,1KW 230/400V VE","KABT/4-6000/450 1,1KW 230/400V VE","KABT/4-6000/450 1,1KW 230/400V VE","0","0","0",2.45,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",630,675,530,450,248,100,215,315,269,40 "KABT/4-9000/500 1,5KW 230/400V","0",90,90,,"0","0","0","0","0",0,0,"0","8413893807762","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-9000/500 1,5KW 230/400V....","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893807762",69,"1",0,0,437,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148519000/1",0,0,0,0,"0",0,0,0,0,9000,"0","0",0,"0","0","0","F","5148519000","5148519000","KABT/4-9000/500 1,5KW 230/400V...","KABT/4-9000/500 1,5KW 230/400V...","KABT/4-9000/500 1,5KW 230/400V...","0","0","0",3.45,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",710,753,590,500,276,100,255,355,293,51.5 "KABT/4-12000/560 2,2KW 230/400V50 VE","0",90,90,,"0","0","0","0","0",0,0,"0","8413893876652","0","0",,0,0,,"0","0","0","0","Cabinet fans manufactured from galvanised steel sheet with double thickness side panels internally lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connectionflange on the inlet. KABT incorporates direct drive backward curvedcentrifugal impeller with motor fitted outside of the air stream, suitable for air stream temperature up to 100ºC. Three phase motor [INDPROT], [CLASEMOTOR]. Motors 4 pole. Electrical supply: [TENSIONTEXT] speedcontrollable by inverter. Working temperature from -20ºC to 100ºC. Trade S&P model KABT/4-12000/560 2,2KW 230/400V50 VE.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893876652",98,"1",0,0,535,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/85/P/5148571300/1",0,0,0,0,"0",0,0,0,0,12000,"0","0",0,"0","0","0","F","5148571300","5148571300","KABT/4-12000/560 2,2KW 230/400V50 VE","KABT/4-12000/560 2,2KW 230/400V50 VE","KABT/4-12000/560 2,2KW 230/400V50 VE","0","0","0",5.01,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,844,680,560,326,100,300,400,343.5,51.5