,AcquisitionDate##OTHER##,Rotation Angle##ANGLE##DEGREES,Rotation Angle Control##ANGLE##DEGREES,ApplicationOfFan##OTHER##,ArticleNumber##OTHER##,AssemblyPlace##OTHER##,AssessmentCondition##OTHER##,AssessmentDate##OTHER##,AssessmentDescription##OTHER##,AtmosphericAcidification##OTHER##,AtmosphericAcidificationPerUnit##OTHER##,Author##OTHER##,BarCode##OTHER##,BIMElementExpiryDate##OTHER##,BIMElementVersion##OTHER##,CapacityControlType##OTHER##,ClimateChange##OTHER##,ClimateChangePerUnit##OTHER##,CoilPosition##OTHER##,ConductorFunction##OTHER##,ContactEmail##OTHER##,ContactTelephone##OTHER##,ContainerMaterial##OTHER##,Description##OTHER##,DirectionOfRotation##OTHER##,DischargePosition##OTHER##,DischargePressureLoss##HVAC_PRESSURE##PASCALS,DischargeVelocity##HVAC_VELOCITY##METERS_PER_SECOND,DrivePowerLoss##HVAC_POWER##WATTS,Air Terminal Velocity Pressure##HVAC_PRESSURE##PASCALS,EfficiencyCurve##OTHER##,Eutrophication##OTHER##,EutrophicationPerUnit##OTHER##,Exclusions##OTHER##,ExpectedServiceLife##OTHER##,FanEfficiency##OTHER##,FanMountingType##OTHER##,FanPowerRate##HVAC_POWER##WATTS,FanRotationSpeed##OTHER##,GlobalTradeItemNumber##OTHER##,GrossWeight##MASS##KILOGRAMS,HasProtectiveEarth##OTHER##,HazardousWaste##OTHER##,HazardousWastePerUnit##OTHER##,ImpellerDiameter##LENGTH##MILLIMETERS,InertWaste##OTHER##,InertWastePerUnit##OTHER##,InstallationDate##OTHER##,InsulationStandardClass##OTHER##,IP_Code##OTHER##,IsExtendedWarranty##OTHER##,LifeCyclePhase##OTHER##,MaintenanceCertificate##OTHER##,MaintenanceCost##OTHER##,MaintenanceFrequency##OTHER##,MaintenanceRegulation##OTHER##,MaintenanceSpecifications##OTHER##,MaintenanceTask##OTHER##,MaintenanceUnit##OTHER##,Manufacturer##OTHER##,MeanTimeBetweenFailure##OTHER##,ModelLabel##OTHER##,MotorDriveType##OTHER##,MotorPosition##OTHER##,NominalAirFlowRate##HVAC_AIR_FLOW##LITERS_PER_SECOND,NominalFrequencyRange##ELECTRICAL_FREQUENCY##HERTZ,NominalPowerRate##ELECTRICAL_POWER##WATTS,NominalRotationSpeed##OTHER##,NominalStaticPressure##HVAC_PRESSURE##PASCALS,NominalTotalPressure##HVAC_PRESSURE##PASCALS,NonHazardousWaste##OTHER##,NonHazardousWastePerUnit##OTHER##,NonRenewableEnergyConsumption##OTHER##,NonRenewableEnergyConsumptionPerUnit##OTHER##,OperationalCriteria##OTHER##,OperationTemperatureRange##OTHER##,OverallEfficiency##OTHER##,PackingCareType##OTHER##,PhotochemicalOzoneFormation##OTHER##,PhotochemicalOzoneFormationPerUnit##OTHER##,PointOfContact##OTHER##,PowerFactor##ELECTRICAL_DEMAND_FACTOR##PERCENTAGE,PressureCurve##OTHER##,ProductionYear##OTHER##,ProductURL##OTHER##,RadioactiveWaste##OTHER##,RadioactiveWastePerUnit##OTHER##,RatedCurrent##ELECTRICAL_CURRENT##AMPERES,RatedVoltage##ELECTRICAL_POTENTIAL##VOLTS,ContactReference##OTHER##,RenewableEnergyConsumption##OTHER##,RenewableEnergyConsumptionPerUnit##OTHER##,ResourceDepletion##OTHER##,ResourceDepletionPerUnit##OTHER##,spFanSize##LENGTH##MILLIMETERS,SerialNumber##OTHER##,ServiceLifeDuration##OTHER##,ShaftPowerRate##HVAC_POWER##WATTS,SoundCurve##OTHER##,spProductQuantity##OTHER##,spTotalProductQuantity##OTHER##,spMotorClass##OTHER##,spProductCode##OTHER##,spEasyVentProductCode##OTHER##,spGenericalProductConfiguration##OTHER##,spProductDescription##OTHER##,spEasyVentProductDescription##OTHER##,spSoundDistance##OTHER##,SpecialInstructions##OTHER##,spIdProject##OTHER##,spMaxAbsorbedCurrent##ELECTRICAL_CURRENT##AMPERES,spProjectLineURL##OTHER##,Arrangement##OTHER##,Model##OTHER##,spProjectName##OTHER##,spPosition##OTHER##,spElectricalPower_Solution##ELECTRICAL_POWER##WATTS,spSpecificPower_Solution##OTHER##,spInletSoundPower##OTHER##,spOutletSoundPower##OTHER##,spBreakOutSoundPower##OTHER##,spShaftPower_Solution##ELECTRICAL_POWER##WATTS,spInletSoundPressure##OTHER##,spOutletSoundPressure##OTHER##,spBreakOutSoundPressure##OTHER##,spReference##OTHER##,spRevision##OTHER##,DischargeType##OTHER##,StratosphericOzoneLayerDestruction##OTHER##,StratosphericOzoneLayerDestructionPerUnit##OTHER##,Throw Distance Medium Velocity##OTHER##,Throw Distance Low Velocity##LENGTH##MILLIMETERS,Throw Distance High Velocity##LENGTH##MILLIMETERS,TotalPrimaryEnergyConsumption##OTHER##,TotalPrimaryEnergyConsumptionPerUnit##OTHER##,Unit##OTHER##,URL##OTHER##,WarrantyContent##OTHER##,WarrantyEndDate##OTHER##,WarrantyStartDate##OTHER##,WaterConsumption##OTHER##,WaterConsumptionPerUnit##OTHER##,WheelTipSpeed##OTHER##,WrappingMaterial##OTHER##,MasterformatCode##OTHER##,MasterformatTitle##OTHER##,Uniclass2.0Code##OTHER##,Uniclass2.0Title##OTHER##,UNSPSCCode##OTHER##,UNSPSCTitle##OTHER##,OmniclassCode##OTHER##,OmniclassTitle##OTHER##,IFCClassification##OTHER##,COBieCategory##OTHER##,Support Bracket Material##OTHER##,PA##LENGTH##MILLIMETERS,PB##LENGTH##MILLIMETERS,PC##LENGTH##MILLIMETERS,PD##LENGTH##MILLIMETERS,PE##LENGTH##MILLIMETERS,PF##LENGTH##MILLIMETERS,PG##LENGTH##MILLIMETERS,PH##LENGTH##MILLIMETERS,PJ##LENGTH##MILLIMETERS,PK##LENGTH##MILLIMETERS,PL##LENGTH##MILLIMETERS "CHAT/4 400 N 0,37KW (230/400V 50) F400 IE2 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892362","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892362",80,"1",0,0,400,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,363,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101200/1",0,0,0,0,"0",0,0,0,0,400,"0","0",0,"0","0","0","H","5148101200","5148101200","CHAT/4 400 N 0,37KW (230/400V 50) F400 IE2 N8","CHAT/4 400 N 0,37KW (230/400V 50) F400 IE2 N8","CHAT/4 400 N 0,37KW (230/400V 50) F400 IE2 N8","0","0","0",0.76,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",650,780,754,400,65,125,104,300,45,40,386 "CHAT/4 450 N 0,55KW (230/400V 50) F400 IE2 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892379","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892379",90,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,696,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101300/1",0,0,0,0,"0",0,0,0,0,450,"0","0",0,"0","0","0","H","5148101300","5148101300","CHAT/4 450 N 0,55KW (230/400V 50) F400 IE2 N8","CHAT/4 450 N 0,55KW (230/400V 50) F400 IE2 N8","CHAT/4 450 N 0,55KW (230/400V 50) F400 IE2 N8","0","0","0",1.83,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",650,760,754,448,55,101,104,300,45,40,386 "CHAT/4 500 N 1,1KW (230/400V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892386","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892386",110,"1",0,0,500,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101400/1",0,0,0,0,"0",0,0,0,0,500,"0","0",0,"0","0","0","H","5148101400","5148101400","CHAT/4 500 N 1,1KW (230/400V 50) F400 IE3 N8.","CHAT/4 500 N 1,1KW (230/400V 50) F400 IE3 N8.","CHAT/4 500 N 1,1KW (230/400V 50) F400 IE3 N8.","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,910,904,498,55,151,104,375,45,40,461 "CHAT/4 560 N 1,5KW (230/400V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892393","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892393",185,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101500/1",0,0,0,0,"0",0,0,0,0,560,"0","0",0,"0","0","0","H","5148101500","5148101500","CHAT/4 560 N 1,5KW (230/400V 50) F400 IE3 N8","CHAT/4 560 N 1,5KW (230/400V 50) F400 IE3 N8","CHAT/4 560 N 1,5KW (230/400V 50) F400 IE3 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",860,970,964,558,55,151,104,405,45,40,470 "CHAT/4 630 N 3,0KW (230/400V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892409","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892409",200,"1",0,0,630,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101600/1",0,0,0,0,"0",0,0,0,0,630,"0","0",0,"0","0","0","H","5148101600","5148101600","CHAT/4 630 N 3,0KW (230/400V 50) F400 IE3 N8","CHAT/4 630 N 3,0KW (230/400V 50) F400 IE3 N8","CHAT/4 630 N 3,0KW (230/400V 50) F400 IE3 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",980,1090,1084,628,55,176,104,465,45,40,530 "CHAT/4 710 N 5,5KW (400/690V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892416","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892416",215,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101700/1",0,0,0,0,"0",0,0,0,0,710,"0","0",0,"0","0","0","H","5148101700","5148101700","CHAT/4 710 N 5,5KW (400/690V 50) F400 IE3 N8","CHAT/4 710 N 5,5KW (400/690V 50) F400 IE3 N8","CHAT/4 710 N 5,5KW (400/690V 50) F400 IE3 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1037,1147,1141,708,55,164.5,104,493.5,45,40,558.5 "CHAT/6 560 N 0,55KW (230/400V 50) F400 IE2 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892423","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892423",185,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,647,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148101900/1",0,0,0,0,"0",0,0,0,0,560,"0","0",0,"0","0","0","H","5148101900","5148101900","CHAT/6 560 N 0,55KW (230/400V 50) F400 IE1 N8","CHAT/6 560 N 0,55KW (230/400V 50) F400 IE1 N8","CHAT/6 560 N 0,55KW (230/400V 50) F400 IE1 N8","0","0","0",1.65,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",860,970,964,558,55,151,104,405,45,40,470 "CHAT/6 630 N 1,1KW (230/400V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892430","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892430",200,"1",0,0,630,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,938,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102000/1",0,0,0,0,"0",0,0,0,0,630,"0","0",0,"0","0","0","H","5148102000","5148102000","CHAT/6 630 N 1,1KW (230/400V 50) F400 IE3 N8","CHAT/6 630 N 1,1KW (230/400V 50) F400 IE3 N8","CHAT/6 630 N 1,1KW (230/400V 50) F400 IE3 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",980,1090,1084,628,55,176,104,465,45,40,530 "CHAT/6 710 N 1,5KW (230/400V 50) F400 IE2 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892447","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892447",215,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102100/1",0,0,0,0,"0",0,0,0,0,710,"0","0",0,"0","0","0","H","5148102100","5148102100","CHAT/6 710 N 1,5KW (230/400V 50) F400 IE2 N8","CHAT/6 710 N 1,5KW (230/400V 50) F400 IE2 N8","CHAT/6 710 N 1,5KW (230/400V 50) F400 IE2 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1037,1147,1141,708,55,164.5,104,493.5,45,40,558.5 "CHAT/6 800 N 3,0KW (230/400V 50) F400 IE3 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892454","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892454",229,"1",0,0,800,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102200/1",0,0,0,0,"0",0,0,0,0,800,"0","0",0,"0","0","0","H","5148102200","5148102200","CHAT/6 800 N 3,0KW (230/400V 50) F400 IE3 N8","CHAT/6 800 N 3,0KW (230/400V 50) F400 IE3 N8","CHAT/6 800 N 3,0KW (230/400V 50) F400 IE3 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1200,1310,1304,798,55,201,104,575,45,40,640 "CHAT/4/8 450 N 0,55/0,09KW (400V 50) F400 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892461","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892461",90,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,754,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102300/1",0,0,0,0,"0",0,0,0,0,450,"0","0",0,"0","0","0","H","5148102300","5148102300","CHAT/4/8 450 N 0,55/0,09KW (400V 50) F400 N8","CHAT/4/8 450 N 0,55/0,09KW (400V 50) F400 N8","CHAT/4/8 450 N 0,55/0,09KW (400V 50) F400 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",650,760,754,448,55,101,104,300,45,40,386 "CHAT/4/8 500 N 1,1/0,18KW (400V 50) F400 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892478","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892478",110,"1",0,0,500,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102400/1",0,0,0,0,"0",0,0,0,0,500,"0","0",0,"0","0","0","H","5148102400","5148102400","CHAT/4/8 500 N 1,1/0,18KW (400V 50) F400 N8","CHAT/4/8 500 N 1,1/0,18KW (400V 50) F400 N8","CHAT/4/8 500 N 1,1/0,18KW (400V 50) F400 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,910,904,498,55,151,104,375,45,40,461 "CHAT/4/8 560 N 1,5/0,25KW (400V 50) F400 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892485","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892485",185,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102500/1",0,0,0,0,"0",0,0,0,0,560,"0","0",0,"0","0","0","H","5148102500","5148102500","CHAT/4/8 560 N 1,5/0,25KW (400V 50) F400 N8","CHAT/4/8 560 N 1,5/0,25KW (400V 50) F400 N8","CHAT/4/8 560 N 1,5/0,25KW (400V 50) F400 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",860,970,964,558,55,151,104,405,45,40,470 "CHAT/4/8 630 N 3,0/0,55KW (400V 50) F400 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892492","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892492",200,"1",0,0,630,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102600/1",0,0,0,0,"0",0,0,0,0,630,"0","0",0,"0","0","0","H","5148102600","5148102600","CHAT/4/8 630 N 3,0/0,55KW (400V 50) F400 N8","CHAT/4/8 630 N 3,0/0,55KW (400V 50) F400 N8","CHAT/4/8 630 N 3,0/0,55KW (400V 50) F400 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",980,1090,1084,628,55,176,104,465,45,40,530 "CHAT/4/8 710 N 5,5/1,1KW (400V 50) F400 N8","0",90,90,,"0","0","0","0","0",0,0,"0","8413893892508","0","0",,0,0,,"0","0","0","0","Direct driven backward curved centrifugal cabinet fan designed for smoke extraction in fire conditions and certified F400-120 (CE marked). The casing is manufactured from a robust galvanised frame work combined with panels lined with 25 mm thickness of fireproof fibreglass acoustic insulation (M0).Class [CLASEMOTOR], [INDPROT] insulation fitted with centrifugal impeller and three phase 230V 50Hz speed controllable motor.","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893892508",215,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/1664/P/5148102700/1",0,0,0,0,"0",0,0,0,0,710,"0","0",0,"0","0","0","H","5148102700","5148102700","CHAT/4/8 710 N 5,5/1,1KW (400V 50) F400 N8","CHAT/4/8 710 N 5,5/1,1KW (400V 50) F400 N8","CHAT/4/8 710 N 5,5/1,1KW (400V 50) F400 N8","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1037,1147,1141,708,55,164.5,104,493.5,45,40,558.5