,AcquisitionDate##OTHER##,Rotation Angle##ANGLE##DEGREES,Rotation Angle Control##ANGLE##DEGREES,ApplicationOfFan##OTHER##,ArticleNumber##OTHER##,AssemblyPlace##OTHER##,AssessmentCondition##OTHER##,AssessmentDate##OTHER##,AssessmentDescription##OTHER##,AtmosphericAcidification##OTHER##,AtmosphericAcidificationPerUnit##OTHER##,Author##OTHER##,BarCode##OTHER##,BIMElementExpiryDate##OTHER##,BIMElementVersion##OTHER##,CapacityControlType##OTHER##,ClimateChange##OTHER##,ClimateChangePerUnit##OTHER##,CoilPosition##OTHER##,ConductorFunction##OTHER##,ContactEmail##OTHER##,ContactTelephone##OTHER##,ContainerMaterial##OTHER##,Description##OTHER##,DirectionOfRotation##OTHER##,DischargePosition##OTHER##,DischargePressureLoss##HVAC_PRESSURE##PASCALS,DischargeVelocity##HVAC_VELOCITY##METERS_PER_SECOND,DrivePowerLoss##HVAC_POWER##WATTS,Air Terminal Velocity Pressure##HVAC_PRESSURE##PASCALS,EfficiencyCurve##OTHER##,Eutrophication##OTHER##,EutrophicationPerUnit##OTHER##,Exclusions##OTHER##,ExpectedServiceLife##OTHER##,FanEfficiency##OTHER##,FanMountingType##OTHER##,FanPowerRate##HVAC_POWER##WATTS,FanRotationSpeed##OTHER##,GlobalTradeItemNumber##OTHER##,GrossWeight##MASS##KILOGRAMS,HasProtectiveEarth##OTHER##,HazardousWaste##OTHER##,HazardousWastePerUnit##OTHER##,ImpellerDiameter##LENGTH##MILLIMETERS,InertWaste##OTHER##,InertWastePerUnit##OTHER##,InstallationDate##OTHER##,InsulationStandardClass##OTHER##,IP_Code##OTHER##,IsExtendedWarranty##OTHER##,LifeCyclePhase##OTHER##,MaintenanceCertificate##OTHER##,MaintenanceCost##OTHER##,MaintenanceFrequency##OTHER##,MaintenanceRegulation##OTHER##,MaintenanceSpecifications##OTHER##,MaintenanceTask##OTHER##,MaintenanceUnit##OTHER##,Manufacturer##OTHER##,MeanTimeBetweenFailure##OTHER##,ModelLabel##OTHER##,MotorDriveType##OTHER##,MotorPosition##OTHER##,NominalAirFlowRate##HVAC_AIR_FLOW##LITERS_PER_SECOND,NominalFrequencyRange##ELECTRICAL_FREQUENCY##HERTZ,NominalPowerRate##ELECTRICAL_POWER##WATTS,NominalRotationSpeed##OTHER##,NominalStaticPressure##HVAC_PRESSURE##PASCALS,NominalTotalPressure##HVAC_PRESSURE##PASCALS,NonHazardousWaste##OTHER##,NonHazardousWastePerUnit##OTHER##,NonRenewableEnergyConsumption##OTHER##,NonRenewableEnergyConsumptionPerUnit##OTHER##,OperationalCriteria##OTHER##,OperationTemperatureRange##OTHER##,OverallEfficiency##OTHER##,PackingCareType##OTHER##,PhotochemicalOzoneFormation##OTHER##,PhotochemicalOzoneFormationPerUnit##OTHER##,PointOfContact##OTHER##,PowerFactor##ELECTRICAL_DEMAND_FACTOR##PERCENTAGE,PressureCurve##OTHER##,ProductionYear##OTHER##,ProductURL##OTHER##,RadioactiveWaste##OTHER##,RadioactiveWastePerUnit##OTHER##,RatedCurrent##ELECTRICAL_CURRENT##AMPERES,RatedVoltage##ELECTRICAL_POTENTIAL##VOLTS,ContactReference##OTHER##,RenewableEnergyConsumption##OTHER##,RenewableEnergyConsumptionPerUnit##OTHER##,ResourceDepletion##OTHER##,ResourceDepletionPerUnit##OTHER##,spFanSize##LENGTH##MILLIMETERS,SerialNumber##OTHER##,ServiceLifeDuration##OTHER##,ShaftPowerRate##HVAC_POWER##WATTS,SoundCurve##OTHER##,spProductQuantity##OTHER##,spTotalProductQuantity##OTHER##,spMotorClass##OTHER##,spProductCode##OTHER##,spEasyVentProductCode##OTHER##,spGenericalProductConfiguration##OTHER##,spProductDescription##OTHER##,spEasyVentProductDescription##OTHER##,spSoundDistance##OTHER##,SpecialInstructions##OTHER##,spIdProject##OTHER##,spMaxAbsorbedCurrent##ELECTRICAL_CURRENT##AMPERES,spProjectLineURL##OTHER##,Arrangement##OTHER##,Model##OTHER##,spProjectName##OTHER##,spPosition##OTHER##,spElectricalPower_Solution##ELECTRICAL_POWER##WATTS,spSpecificPower_Solution##OTHER##,spInletSoundPower##OTHER##,spOutletSoundPower##OTHER##,spBreakOutSoundPower##OTHER##,spShaftPower_Solution##ELECTRICAL_POWER##WATTS,spInletSoundPressure##OTHER##,spOutletSoundPressure##OTHER##,spBreakOutSoundPressure##OTHER##,spReference##OTHER##,spRevision##OTHER##,DischargeType##OTHER##,StratosphericOzoneLayerDestruction##OTHER##,StratosphericOzoneLayerDestructionPerUnit##OTHER##,Throw Distance Medium Velocity##OTHER##,Throw Distance Low Velocity##LENGTH##MILLIMETERS,Throw Distance High Velocity##LENGTH##MILLIMETERS,TotalPrimaryEnergyConsumption##OTHER##,TotalPrimaryEnergyConsumptionPerUnit##OTHER##,Unit##OTHER##,URL##OTHER##,WarrantyContent##OTHER##,WarrantyEndDate##OTHER##,WarrantyStartDate##OTHER##,WaterConsumption##OTHER##,WaterConsumptionPerUnit##OTHER##,WheelTipSpeed##OTHER##,WrappingMaterial##OTHER##,MasterformatCode##OTHER##,MasterformatTitle##OTHER##,Uniclass2.0Code##OTHER##,Uniclass2.0Title##OTHER##,UNSPSCCode##OTHER##,UNSPSCTitle##OTHER##,OmniclassCode##OTHER##,OmniclassTitle##OTHER##,IFCClassification##OTHER##,COBieCategory##OTHER##,Support Bracket Material##OTHER##,PA##LENGTH##MILLIMETERS,PB##LENGTH##MILLIMETERS,PC##LENGTH##MILLIMETERS,PD##LENGTH##MILLIMETERS,PD1##LENGTH##MILLIMETERS,PE##LENGTH##MILLIMETERS,PF##LENGTH##MILLIMETERS,PG##LENGTH##MILLIMETERS,PJ##LENGTH##MILLIMETERS "HCBT/6-1000/H-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893095190","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-1000/H-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893095190",60,"1",0,0,1000,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,2791.105713,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604248400/1",0,0,0,0,"0",0,0,0,0,1000,"0","0",0,"0","0","0","F","5604248400","5604248400","HCBT/6-1000/H-AX (230/400V50HZ) V5","HCBT/6-1000/H-AX (230/400V50HZ) V5","HCBT/6-1000/H-AX (230/400V50HZ) V5","0","0","0",4.42,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1250,1000,400,1000,1010,18,200,1154,110 "HCBT/6-1000/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893095206","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-1000/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893095206",54,"1",0,0,1000,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,1846.903442,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604249200/1",0,0,0,0,"0",0,0,0,0,1000,"0","0",0,"0","0","0","F","5604249200","5604249200","HCBT/6-1000/L-AX (230/400V50HZ) V5","HCBT/6-1000/L-AX (230/400V50HZ) V5","HCBT/6-1000/L-AX (230/400V50HZ) V5","0","0","0",3.39,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1250,1000,400,1000,1010,18,200,1154,110 "HCBT/4-1000/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893101235","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/4-1000/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893101235",67,"1",0,0,1000,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,5044.258301,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604377100/1",0,0,0,0,"0",0,0,0,0,1000,"0","0",0,"0","0","0","F","5604377100","5604377100","HCBT/4-1000/L-AX (230/400V50HZ) V5","HCBT/4-1000/L-AX (230/400V50HZ) V5","HCBT/4-1000/L-AX (230/400V50HZ) V5","0","0","0",8.22,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1250,1000,442,1000,1010,18,200,1154,110 "HCBT/4-800/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893101433","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/4-800/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893101433",37,"1",0,0,800,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,2632.218506,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604383900/1",0,0,0,0,"0",0,0,0,0,800,"0","0",0,"0","0","0","F","5604383900","5604383900","HCBT/4-800/L-AX (230/400V50HZ) V5","HCBT/4-800/L-AX (230/400V50HZ) V5","HCBT/4-800/L-AX (230/400V50HZ) V5","0","0","0",4.24,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1000,800,363,800,810,18,180,926,92 "HCBT/4-800/H-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893101457","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/4-800/H-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893101457",52,"1",0,0,800,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,4589.85498,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604385400/1",0,0,0,0,"0",0,0,0,0,800,"0","0",0,"0","0","0","F","5604385400","5604385400","HCBT/4-800/H-AX (230/400V50HZ) V5","HCBT/4-800/H-AX (230/400V50HZ) V5","HCBT/4-800/H-AX (230/400V50HZ) V5","0","0","0",7.42,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1000,800,442,800,810,18,200,926,92 "HCBT/6-800/H-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893101464","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-800/H-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893101464",36,"1",0,0,800,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,1307.675781,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604386200/1",0,0,0,0,"0",0,0,0,0,800,"0","0",0,"0","0","0","F","5604386200","5604386200","HCBT/6-800/H-AX (230/400V50HZ) V5","HCBT/6-800/H-AX (230/400V50HZ) V5","HCBT/6-800/H-AX (230/400V50HZ) V5","0","0","0",2.42,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1000,800,363,800,810,18,180,926,92 "HCBT/6-800/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893636966","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-800/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893636966",31,"1",0,0,800,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,1023.085449,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5604390500/1",0,0,0,0,"0",0,0,0,0,800,"0","0",0,"0","0","0","F","5604390500","5604390500","HCBT/6-800/L-AX (230/400V50HZ) V5","HCBT/6-800/L-AX (230/400V50HZ) V5","HCBT/6-800/L-AX (230/400V50HZ) V5","0","0","0",1.9,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1000,800,318,800,810,18,160,926,92 "HCBT/4-900/H-AX (400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893182616","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/4-900/H-AX (400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893182616",96,"1",0,0,900,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5605572600/1",0,0,0,0,"0",0,0,0,0,900,"0","0",0,"0","0","0","F","5605572600","5605572600","HCBT/4-900/H-AX (400V50HZ) V5","HCBT/4-900/H-AX (400V50HZ) V5","HCBT/4-900/H-AX (400V50HZ) V5","0","0","0",0,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1120,900,512,900,910,18,280,1060,120 "HCBT/4-900/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893212894","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/4-900/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893212894",62,"1",0,0,900,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,3907.872803,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5605723500/1",0,0,0,0,"0",0,0,0,0,900,"0","0",0,"0","0","0","F","5605723500","5605723500","HCBT/4-900/L-AX (230/400V50HZ) V5","HCBT/4-900/L-AX (230/400V50HZ) V5","HCBT/4-900/L-AX (230/400V50HZ) V5","0","0","0",6.93,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1120,900,442,900,910,18,200,1060,120 "HCBT/6-900/L-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893212900","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-900/L-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893212900",54,"1",0,0,900,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,1340.806519,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5605724300/1",0,0,0,0,"0",0,0,0,0,900,"0","0",0,"0","0","0","F","5605724300","5605724300","HCBT/6-900/L-AX (230/400V50HZ) V5","HCBT/6-900/L-AX (230/400V50HZ) V5","HCBT/6-900/L-AX (230/400V50HZ) V5","0","0","0",2.82,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1120,900,400,900,910,18,200,1060,120 "HCBT/6-900/H-AX (230/400V50HZ) V5","0",90,90,,"0","0","0","0","0",0,0,"0","8413893212917","0","0",,0,0,,"0","0","0","0","Range of low profile plate mounted axial fans fitted with aluminium impellers and three phase motor (HCBT), [INDPROT] , Class [CLASEMOTOR] insulation (2), equipped with thermal protection*. *Except models Ø 800 to 1000.Motors Available, depending upon the model, with single or three phase motors in 4 or 6 poles. All motors are speed controllable by autotransformer except models /4-630, B/710, T/4-710, T/800, T/900 and T/1000.Three phase models are speed controllable by inverter.Electrical supplies:Three phase 230/400V-50Hz or 400V-50Hz.Trade S&P model HCBT/6-900/H-AX (230/400V50HZ) V5","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893212917",57,"1",0,0,900,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,2370.281006,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/174/P/5605725000/1",0,0,0,0,"0",0,0,0,0,900,"0","0",0,"0","0","0","F","5605725000","5605725000","HCBT/6-900/H-AX (230/400V50HZ) V5","HCBT/6-900/H-AX (230/400V50HZ) V5","HCBT/6-900/H-AX (230/400V50HZ) V5","0","0","0",4.21,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1120,900,400,900,910,18,200,1060,120