,AcquisitionDate##OTHER##,Rotation Angle##ANGLE##DEGREES,Rotation Angle Control##ANGLE##DEGREES,ApplicationOfFan##OTHER##,ArticleNumber##OTHER##,AssemblyPlace##OTHER##,AssessmentCondition##OTHER##,AssessmentDate##OTHER##,AssessmentDescription##OTHER##,AtmosphericAcidification##OTHER##,AtmosphericAcidificationPerUnit##OTHER##,Author##OTHER##,BarCode##OTHER##,BIMElementExpiryDate##OTHER##,BIMElementIssueDate##OTHER##,BIMElementVersion##OTHER##,CapacityControlType##OTHER##,ClimateChange##OTHER##,ClimateChangePerUnit##OTHER##,CoilPosition##OTHER##,ConductorFunction##OTHER##,ContactEmail##OTHER##,ContactTelephone##OTHER##,ContainerMaterial##OTHER##,Description##OTHER##,DirectionOfRotation##OTHER##,DischargePosition##OTHER##,DischargePressureLoss##HVAC_PRESSURE##PASCALS,DischargeVelocity##HVAC_VELOCITY##METERS_PER_SECOND,DrivePowerLoss##HVAC_POWER##WATTS,Air Terminal Velocity Pressure##HVAC_PRESSURE##PASCALS,EfficiencyCurve##OTHER##,Eutrophication##OTHER##,EutrophicationPerUnit##OTHER##,Exclusions##OTHER##,ExpectedServiceLife##OTHER##,FanEfficiency##OTHER##,FanMountingType##OTHER##,FanPowerRate##HVAC_POWER##WATTS,FanRotationSpeed##OTHER##,GlobalTradeItemNumber##OTHER##,GrossWeight##MASS##KILOGRAMS,HasProtectiveEarth##OTHER##,HazardousWaste##OTHER##,HazardousWastePerUnit##OTHER##,ImpellerDiameter##LENGTH##MILLIMETERS,InertWaste##OTHER##,InertWastePerUnit##OTHER##,InstallationDate##OTHER##,InsulationStandardClass##OTHER##,IP_Code##OTHER##,IsExtendedWarranty##OTHER##,LifeCyclePhase##OTHER##,MaintenanceCertificate##OTHER##,MaintenanceCost##OTHER##,MaintenanceFrequency##OTHER##,MaintenanceRegulation##OTHER##,MaintenanceSpecifications##OTHER##,MaintenanceTask##OTHER##,MaintenanceUnit##OTHER##,Manufacturer##OTHER##,MeanTimeBetweenFailure##OTHER##,ModelLabel##OTHER##,MotorDriveType##OTHER##,MotorPosition##OTHER##,NominalAirFlowRate##HVAC_AIR_FLOW##LITERS_PER_SECOND,NominalFrequencyRange##ELECTRICAL_FREQUENCY##HERTZ,NominalPowerRate##ELECTRICAL_POWER##WATTS,NominalRotationSpeed##OTHER##,NominalStaticPressure##HVAC_PRESSURE##PASCALS,NominalTotalPressure##HVAC_PRESSURE##PASCALS,NonHazardousWaste##OTHER##,NonHazardousWastePerUnit##OTHER##,NonRenewableEnergyConsumption##OTHER##,NonRenewableEnergyConsumptionPerUnit##OTHER##,OperationalCriteria##OTHER##,OperationTemperatureRange##OTHER##,OverallEfficiency##OTHER##,PackingCareType##OTHER##,PhotochemicalOzoneFormation##OTHER##,PhotochemicalOzoneFormationPerUnit##OTHER##,PointOfContact##OTHER##,PowerFactor##ELECTRICAL_DEMAND_FACTOR##PERCENTAGE,PressureCurve##OTHER##,ProductionYear##OTHER##,ProductURL##OTHER##,RadioactiveWaste##OTHER##,RadioactiveWastePerUnit##OTHER##,RatedCurrent##ELECTRICAL_CURRENT##AMPERES,RatedVoltage##ELECTRICAL_POTENTIAL##VOLTS,ContactReference##OTHER##,RenewableEnergyConsumption##OTHER##,RenewableEnergyConsumptionPerUnit##OTHER##,ResourceDepletion##OTHER##,ResourceDepletionPerUnit##OTHER##,spFanSize##LENGTH##MILLIMETERS,SerialNumber##OTHER##,ServiceLifeDuration##OTHER##,ShaftPowerRate##HVAC_POWER##WATTS,SoundCurve##OTHER##,spProductQuantity##OTHER##,spTotalProductQuantity##OTHER##,spMotorClass##OTHER##,spProductCode##OTHER##,spEasyVentProductCode##OTHER##,spGenericalProductConfiguration##OTHER##,spProductDescription##OTHER##,spEasyVentProductDescription##OTHER##,spSoundDistance##OTHER##,SpecialInstructions##OTHER##,spIdProject##OTHER##,spMaxAbsorbedCurrent##ELECTRICAL_CURRENT##AMPERES,spProjectLineURL##OTHER##,Arrangement##OTHER##,Model##OTHER##,spProjectName##OTHER##,spPosition##OTHER##,spElectricalPower_Solution##ELECTRICAL_POWER##WATTS,spSpecificPower_Solution##OTHER##,spInletSoundPower##OTHER##,spOutletSoundPower##OTHER##,spBreakOutSoundPower##OTHER##,spShaftPower_Solution##ELECTRICAL_POWER##WATTS,spInletSoundPressure##OTHER##,spOutletSoundPressure##OTHER##,spBreakOutSoundPressure##OTHER##,spReference##OTHER##,spRevision##OTHER##,DischargeType##OTHER##,StratosphericOzoneLayerDestruction##OTHER##,StratosphericOzoneLayerDestructionPerUnit##OTHER##,Throw Distance Medium Velocity##OTHER##,Throw Distance Low Velocity##LENGTH##MILLIMETERS,Throw Distance High Velocity##LENGTH##MILLIMETERS,TotalPrimaryEnergyConsumption##OTHER##,TotalPrimaryEnergyConsumptionPerUnit##OTHER##,Unit##OTHER##,URL##OTHER##,WarrantyContent##OTHER##,WarrantyEndDate##OTHER##,WarrantyStartDate##OTHER##,WaterConsumption##OTHER##,WaterConsumptionPerUnit##OTHER##,WheelTipSpeed##OTHER##,WrappingMaterial##OTHER##,MasterformatCode##OTHER##,MasterformatTitle##OTHER##,Uniclass2.0Code##OTHER##,Uniclass2.0Title##OTHER##,UNSPSCCode##OTHER##,UNSPSCTitle##OTHER##,OmniclassCode##OTHER##,OmniclassTitle##OTHER##,IFCClassification##OTHER##,COBieCategory##OTHER##,Support Bracket Material##OTHER##,PA##LENGTH##MILLIMETERS,PB##LENGTH##MILLIMETERS,PD##LENGTH##MILLIMETERS,PE##LENGTH##MILLIMETERS,PF##LENGTH##MILLIMETERS "TCDH EXD 010-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288608","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 010-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288608",22,"1",0,0,250,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,67.53851318,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136611700/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136611700","5136611700","TCDH EXD 010-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 010-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 010-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0","0","0",1.2,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",430,405,181,344,30 "TCDH EXD 020-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288615","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 020-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288615",25,"1",0,0,250,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,213.1239929,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136611800/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136611800","5136611800","TCDH EXD 020-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 020-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 020-4 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0","0","0",1.2,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",430,430,217,344,30 "TCDH EXD 030-4 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288622","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 030-4 IIBH2 T4 0,37KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288622",0,"1",0,0,315,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,428,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136611900/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136611900","5136611900","TCDH EXD 030-4 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 030-4 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 030-4 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0","0","0",1.5,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",540,539,256,450,30 "TCDH EXD 040-4 IIBH2 T4 0,55KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288639","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 040-4 IIBH2 T4 0,55KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288639",0,"1",0,0,315,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,857,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612000/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612000","5136612000","TCDH EXD 040-4 IIBH2 T4 0,55KW (230/400V50HZ) PTC","TCDH EXD 040-4 IIBH2 T4 0,55KW (230/400V50HZ) PTC","TCDH EXD 040-4 IIBH2 T4 0,55KW (230/400V50HZ) PTC","0","0","0",1.7,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",540,562,294,450,30 "TCDH EXD 060-4 IIBH2 T4 0,75KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288646","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 060-4 IIBH2 T4 0,75KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288646",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612100/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612100","5136612100","TCDH EXD 060-4 IIBH2 T4 0,75KW (230/400V50HZ) PTC","TCDH EXD 060-4 IIBH2 T4 0,75KW (230/400V50HZ) PTC","TCDH EXD 060-4 IIBH2 T4 0,75KW (230/400V50HZ) PTC","0","0","0",2.2,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,650,326,570,30 "TCDH EXD 080-4 IIBH2 T4 1,5KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288653","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 080-4 IIBH2 T4 1,5KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288653",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612200/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612200","5136612200","TCDH EXD 080-4 IIBH2 T4 1,5KW (230/400V50HZ) PTC","TCDH EXD 080-4 IIBH2 T4 1,5KW (230/400V50HZ) PTC","TCDH EXD 080-4 IIBH2 T4 1,5KW (230/400V50HZ) PTC","0","0","0",4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,662,362,570,30 "TCDH EXD 105-4 IIBH2 T4 2,2KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288660","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 105-4 IIBH2 T4 2,2KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288660",0,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612300/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612300","5136612300","TCDH EXD 105-4 IIBH2 T4 2,2KW (230/400V50HZ) PTC","TCDH EXD 105-4 IIBH2 T4 2,2KW (230/400V50HZ) PTC","TCDH EXD 105-4 IIBH2 T4 2,2KW (230/400V50HZ) PTC","0","0","0",5.2,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,726,399,668,30 "TCDH EXD 020-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288844","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 020-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288844",32,"1",0,0,250,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,64.46512406,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612400/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612400","5136612400","TCDH EXD 020-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 020-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 020-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0","0","0",1,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",430,430,217,344,30 "TCDH EXD 030-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288677","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 030-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288677",0,"1",0,0,315,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,127,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612500/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612500","5136612500","TCDH EXD 030-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 030-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 030-6 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0","0","0",1,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",540,539,256,450,30 "TCDH EXD 040-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288684","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 040-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288684",0,"1",0,0,315,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,254,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612600/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612600","5136612600","TCDH EXD 040-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 040-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 040-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0","0","0",1.4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",540,562,294,450,30 "TCDH EXD 060-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288691","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 060-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288691",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,358,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612700/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612700","5136612700","TCDH EXD 060-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 060-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","TCDH EXD 060-6 IIBH2 T4 0,25KW (230/400V50HZ) PTC","0","0","0",1.4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,650,326,570,30 "TCDH EXD 080-6 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288707","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 080-6 IIBH2 T4 0,37KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288707",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,529,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612800/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612800","5136612800","TCDH EXD 080-6 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 080-6 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 080-6 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0","0","0",1.6,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,662,362,570,30 "TCDH EXD 105-6 IIBH2 T4 0,75KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288714","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 105-6 IIBH2 T4 0,75KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288714",0,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,815,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136612900/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136612900","5136612900","TCDH EXD 105-6 IIBH2 T4 0,75KW (230/400V50HZ) PTC","TCDH EXD 105-6 IIBH2 T4 0,75KW (230/400V50HZ) PTC","TCDH EXD 105-6 IIBH2 T4 0,75KW (230/400V50HZ) PTC","0","0","0",2.4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,726,399,668,30 "TCDH EXD 110-6 IIBH2 T4 1,1KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288721","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 110-6 IIBH2 T4 1,1KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288721",0,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613000/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613000","5136613000","TCDH EXD 110-6 IIBH2 T4 1,1KW (230/400V50HZ) PTC","TCDH EXD 110-6 IIBH2 T4 1,1KW (230/400V50HZ) PTC","TCDH EXD 110-6 IIBH2 T4 1,1KW (230/400V50HZ) PTC","0","0","0",3.4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,759,444,668,30 "TCDH EXD 140-6 IIBH2 T4 2,2KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288738","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 140-6 IIBH2 T4 2,2KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288738",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613100/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613100","5136613100","TCDH EXD 140-6 IIBH2 T4 2,2KW (230/400V50HZ) PTC","TCDH EXD 140-6 IIBH2 T4 2,2KW (230/400V50HZ) PTC","TCDH EXD 140-6 IIBH2 T4 2,2KW (230/400V50HZ) PTC","0","0","0",5.4,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",946,876,490,830,30 "TCDH EXD 195-6 IIBH2 T4 3KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288745","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 195-6 IIBH2 T4 3KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288745",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613200/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613200","5136613200","TCDH EXD 195-6 IIBH2 T4 3KW (230/400V50HZ) PTC","TCDH EXD 195-6 IIBH2 T4 3KW (230/400V50HZ) PTC","TCDH EXD 195-6 IIBH2 T4 3KW (230/400V50HZ) PTC","0","0","0",8.5,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",946,900,537,830,30 "TCDH EXD 250-6 IIBH2 T4 5,5KW (400/690V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288752","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 250-6 IIBH2 T4 5,5KW (400/690V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288752",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613300/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613300","5136613300","TCDH EXD 250-6 IIBH2 T4 5,5KW (400/690V50HZ) PTC","TCDH EXD 250-6 IIBH2 T4 5,5KW (400/690V50HZ) PTC","TCDH EXD 250-6 IIBH2 T4 5,5KW (400/690V50HZ) PTC","0","0","0",14,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1030,940,581,830,40 "TCDH EXD 060-8 IIBH2 T4 0,12KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288769","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 060-8 IIBH2 T4 0,12KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288769",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,151,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613400/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613400","5136613400","TCDH EXD 060-8 IIBH2 T4 0,12KW (230/400V50HZ) PTC","TCDH EXD 060-8 IIBH2 T4 0,12KW (230/400V50HZ) PTC","TCDH EXD 060-8 IIBH2 T4 0,12KW (230/400V50HZ) PTC","0","0","0",0.85,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,650,326,570,30 "TCDH EXD 080-8 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288776","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 080-8 IIBH2 T4 0,18KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288776",0,"1",0,0,450,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,223,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613500/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613500","5136613500","TCDH EXD 080-8 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 080-8 IIBH2 T4 0,18KW (230/400V50HZ) PTC","TCDH EXD 080-8 IIBH2 T4 0,18KW (230/400V50HZ) PTC","0","0","0",1.15,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",660,662,362,570,30 "TCDH EXD 105-8 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288783","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 105-8 IIBH2 T4 0,37KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288783",0,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,344,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613600/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613600","5136613600","TCDH EXD 105-8 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 105-8 IIBH2 T4 0,37KW (230/400V50HZ) PTC","TCDH EXD 105-8 IIBH2 T4 0,37KW (230/400V50HZ) PTC","0","0","0",1.5,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,726,399,668,30 "TCDH EXD 110-8 IIBH2 T4 0,55KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288790","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 110-8 IIBH2 T4 0,55KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288790",0,"1",0,0,560,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,634,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613700/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613700","5136613700","TCDH EXD 110-8 IIBH2 T4 0,55KW (230/400V50HZ) PTC","TCDH EXD 110-8 IIBH2 T4 0,55KW (230/400V50HZ) PTC","TCDH EXD 110-8 IIBH2 T4 0,55KW (230/400V50HZ) PTC","0","0","0",2.1,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",800,759,444,668,30 "TCDH EXD 140-8 IIBH2 T4 1,1KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288806","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 140-8 IIBH2 T4 1,1KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288806",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,994,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613800/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613800","5136613800","TCDH EXD 140-8 IIBH2 T4 1,1KW (230/400V50HZ) PTC","TCDH EXD 140-8 IIBH2 T4 1,1KW (230/400V50HZ) PTC","TCDH EXD 140-8 IIBH2 T4 1,1KW (230/400V50HZ) PTC","0","0","0",4.1,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",946,876,490,830,30 "TCDH EXD 195-8 IIBH2 T4 1,5KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288813","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 195-8 IIBH2 T4 1,5KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288813",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136613900/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136613900","5136613900","TCDH EXD 195-8 IIBH2 T4 1,5KW (230/400V50HZ) PTC","TCDH EXD 195-8 IIBH2 T4 1,5KW (230/400V50HZ) PTC","TCDH EXD 195-8 IIBH2 T4 1,5KW (230/400V50HZ) PTC","0","0","0",4.8,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",946,900,537,830,30 "TCDH EXD 250-8 IIBH2 T4 3KW (230/400V50HZ) PTC","0",90,90,,"0","0","0","0","0",0,0,"0","8413893288820","2022-02-07","2024-07-12","0",,0,0,,"0","0","0","0","Centrifugal roof fan in horizontal discharge format. Direct drive backward curved centrifugal impeller manufactured from galvanized sheet steel y aluminium hub. Base manufactured from galvanized sheet steel and brass inlet ring. Cowl manufactured from galvanised sheet steel with grey epoxy paint coating. Specially designed for the ventilation / extraction of potentially hazardous and explosive gases. Three phase motors [INDPROT], [CLASEMOTOR], EExd IIBT4 or EExd IICT4. S&P model TCDH EXD 250-8 IIBH2 T4 3KW (230/400V50HZ) PTC .","0","0",0,0,0,0,"0",0,0,"0","0","0",,0,"0","8413893288820",0,"1",0,0,710,0,0,"0","0","IP55","0","0","0",0,"0","0","0","0","0","ELEKTRODESIGN VENTILATORY, SPOL.S.R.O.","0","0",,,0,0,0,0,0,0,0,0,0,0,"0","0","0","0",0,0,"0",0,"0","0","https://easyvent.solerpalau.com/fan-info/view/00047/47/89/P/5136614000/1",0,0,0,400,"0",0,0,0,0,0,"0","0",0,"0","0","0","F","5136614000","5136614000","TCDH EXD 250-8 IIBH2 T4 3KW (230/400V50HZ) PTC","TCDH EXD 250-8 IIBH2 T4 3KW (230/400V50HZ) PTC","TCDH EXD 250-8 IIBH2 T4 3KW (230/400V50HZ) PTC","0","0","0",8.7,"0","0","0","0","0",0,"0","0","0","0",0,"0","0","0","0","0",,0,0,"0",0,"0",0,0,"0","https://www.solerpalau.com/","0","0","0",0,0,"0","0","0","0","0","0","0","0","0","0","0","0","0",1030,940,581,830,40